Validation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone

نویسندگان

  • G. B. Osterman
  • S. S. Kulawik
  • H. M. Worden
  • N. A. D. Richards
  • B. M. Fisher
  • A. Eldering
  • M. W. Shephard
  • L. Froidevaux
  • G. Labow
  • M. Luo
  • R. L. Herman
  • K. W. Bowman
  • A. M. Thompson
چکیده

[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and aircraft measurements. TES measurements also have sensitivity throughout the stratosphere, and therefore TES ozone profiles can be integrated to determine the total and stratospheric column in addition to the tropospheric column ozone values. In this work we compare the ozone in the stratosphere measured by TES to observations from the Microwave Limb Sounder (MLS) instrument in order to show the quality of the TES measurements in the stratosphere. We also compare the determination of a total column value for ozone based on the TES profiles to the column measured by the Ozone Monitoring Instrument (OMI). The TES tropospheric ozone column value is also calculated from the TES profiles and compared with column values determined from ozonesonde data. Column measurements are useful because the errors are markedly reduced from errors at the profile levels and can be used to assess both biases and quality of the TES ozone retrievals. TES observations of total or partial column ozone compare well with the other instruments but tend toward higher values than the other measurements. Specifically, TES is higher than OMI by 10 Dobson units (DU) for the total ozone column. TES measures higher values in the stratosphere (above 100 hPa) by 3 DU and measures higher ozone column values ( 4 DU) in the troposphere than ozonesondes. While the strength of the TES nadir ozone product is the vertical resolution it provides in the troposphere, a tropospheric column value derived from TES have utility in analyses using or validating tropospheric ozone residual products.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of Tropospheric Emission Spectrometer ozone profiles with aircraft observations during the Intercontinental Chemical Transport Experiment–B

[1] The Tropospheric Emission Spectrometer (TES) is an infrared instrument that was launched on board NASA’s Aura satellite in 2004. TES is the first instrument to provide vertical information on tropospheric ozone while simultaneously measuring CO on a global basis. Before they may be used for scientific study, TES profiles must first be validated to determine if there are any systematic biase...

متن کامل

Tropospheric column ozone: matching individual profiles from Aura OMI and TES with a chemistry-transport model

Of all satellite measurements of ozone, only two instruments have coincident, spatially overlapping measurements to allow direct comparison of tropospheric column ozone (TCO): the Ozone Monitoring Instrument (OMI) and the Tropospheric Emission Spectrometer (TES) on the NASA Aura spacecraft. For two years (2005–2006), we collect all observations between 60 S and 60 N from nadir (∼65 000 from OMI...

متن کامل

Validation of version 5.20 ILAS HNO3, CH4, N2O, O3, and NO2 using ground-based measurements at Arrival Heights and Kiruna

Ground-based measurements of O3 and NO2 columns at Kiruna (68°N) and Arrival Heights (78°S) were used to validate stratospheric profile measurements of the same species by the satellite-based Improved Limb Atmospheric Spectrometer (ILAS) flown between November 1996 and June 1997. In addition, measurements of HNO3, CH4, and N2O made at Arrival Heights are compared with measurements of these spec...

متن کامل

Intercomparison methods for satellite measurements of atmospheric composition: application to tropospheric ozone from TES and OMI

We analyze the theoretical basis of three different methods to validate and intercompare satellite measurements of atmospheric composition, and apply them to tropospheric ozone retrievals from the Tropospheric Emission Spectrometer (TES) and the Ozone Monitoring Instrument (OMI). The first method (in situ method) uses in situ vertical profiles for absolute instrument validation; it is limited b...

متن کامل

Tropospheric ozone variations governed by changes in stratospheric circulation

Thedownward transport of stratospheric ozone is an important natural source of tropospheric ozone, particularly in the upper troposphere, where changes in ozone have their largest radiative e ect1. Stratospheric circulation is projected to intensify over the coming century, which could lead to an increase in the flux of ozone from the stratosphere to the troposphere2–4. However, large uncertain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008