Comparison of the accuracy of transpulmonary thermodilution measurement using indicators of different temperatures.
نویسندگان
چکیده
Transpulmonary thermodilution measurement is a convenient method for hemodynamic monitoring. However, the previously reported indicator temperature was not consistent. This study aimed to compare the accuracy of Pulse index Continuous Cardiac Output (PiCCO) monitoring using indicators of different temperatures. A total of 104 critically ill patients received PiCCO monitoring using indicators of either 0°C or 8°C. The PiCCO measurements, including general ejection fraction, global end-diastolic index, and cardiac index, were compared between the two temperatures, and were also correlated with that of transesophageal echocardiography (TEE). The two indicator temperatures differed significantly in hemodynamic measurements (P<0.01). PiCCO measurements with either indicator temperatures showed positive correlation with TEE results (P<0.05). The 0°C indicator had universally higher correlation coefficients than the 8°C indicator. So, PiCCO monitoring with the 0°C indicator might have better accuracy than the 8°C indicator.
منابع مشابه
Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.
BACKGROUND Recently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients. METHODS We studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, ag...
متن کاملValidation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study
INTRODUCTION Gravimetric validation of single-indicator extravascular lung water (EVLW) and normal EVLW values has not been well studied in humans thus far. The aims of this study were (1) to validate the accuracy of EVLW measurement by single transpulmonary thermodilution with postmortem lung weight measurement in humans and (2) to define the statistically normal EVLW values. METHODS We eval...
متن کاملAccuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution
Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A ...
متن کاملThe Echocardiographic Tei-index Compared to Transpulmonary Thermodilution Measurement With Different Hemodynamic Biomodels
متن کامل
A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery
Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of clinical and experimental medicine
دوره 7 12 شماره
صفحات -
تاریخ انتشار 2014