Interpretation of heterogeneity effects in synchrotron X-ray fluorescence microprobe data

نویسندگان

  • Mavrik Zavarin
  • Harvey E Doner
چکیده

Heterogeneity effects often limit the accuracy of synchrotron X-ray fluorescence microprobe elemental analysis data to ¡30%. The difference in matrix mass absorption at Ka and Kb fluorescence energies of a particular element can be exploited to yield information on the average depth-position of the element or account for heterogeneity effects. Using this technique, the heterogeneous distribution of Cu in a simple layered sample could be resolved to a 2 6 2 6 10 (x, y, z, where z is the depth coordinate) micrometer scale; a depth-resolution limit was determined for the first transition metal series and several other elements in calcite and iron oxide matrices. For complex heterogeneous systems, determination of average element depth may be computationally limited but the influence of heterogeneity on fluorescence data may still be assessed. We used this method to compare solid-state diffusion with sample heterogeneity across the Ni-serpentine/calcite boundary of a rock from Panoche Creek, California. We previously reported that Ni fluorescence data may indicate solid state diffusion; in fact, sample heterogeneity in the depth dimension can also explain the Ni fluorescence data. Depth heterogeneity in samples can lead to misinterpretation of synchrotron X-ray microprobe results unless care is taken to account for the influence of heterogeneity on fluorescence data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Major-element ratios in synthetic fluid inclusions by synchrotron X-ray fluorescence microprobe

Individual fluid inclusions in quartz were investigated by synchrotron radiation X-ray fluorescence (SXRF) microprobe to develop protocols for major-element microanalysis. Studies were conducted of synthetic fluid inclusions in Brazilian quartz that contain fluids of known NaC1-CaC12-H20 and KCI-H20 compositions. Inclusions were irradiated by synchrotron X-rays and the resulting energy-dispersi...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

Synchrotron-based Spectroscopic Studies of Metal Species in Solid Phases: the Case of Arsenic

The production of high-energy (1 KeV to 40 KeV) x-radiation at synchrotron laboratories around the world has enabled the spectroscopic analysis of core level electronic transitions and electronic scattering processes in trace (< 1000 ppm) metal and metalloid atoms as they are found in heterogeneous natural materials (e.g., soils, sediments, plants, and microbial mats). Environmental geochemists...

متن کامل

Synchrotron radiation identified human chemical fingerprints – a novel forensic approach

Synchrotron radiation x-ray fluorescence microprobe and infrared spectromicroscopy have been used to generate fundamental data and to analyze and visualize latent human fingerprints with the goal of developing an advanced forensic technique to identify complicated partial latent prints. The chemical composition of fingerprints (sweat) is well documented in medical literature, and techniques abo...

متن کامل

Differential phase contrast with a segmented detector in a scanning X-ray microprobe.

Scanning X-ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi-keV range. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Geochemical Transactions

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2002