Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU.

نویسندگان

  • Kyung Sang Kim
  • Jong Chul Ye
چکیده

Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125× and 141× for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph.

UNLABELLED The high-resolution research tomograph (HRRT) is a dedicated human brain PET scanner. At present, iterative reconstruction methods are preferred for reconstructing HRRT studies. However, these iterative reconstruction algorithms show bias in short-duration frames. New algorithms such as the shifted Poisson ordered-subsets expectation maximization (SP-OSEM) and ordered-subsets weighte...

متن کامل

LOR-OSEM: Statistical PET Reconstruction from Raw LOR Histograms

Iterative statistical reconstruction methods are becoming the standard in positron emission tomography (PET). Conventional maximum-likelihood expectation-maximization (MLEM) and ordered-subsets (OSEM) algorithms act on data which has been pre-processed into corrected, evenly-spaced histograms; however, such pre-processing corrupts the Poisson statistics. Recent advances have incorporated attenu...

متن کامل

Assessment of the impact of model-based scatter correction on [18F]-FDG 3D brain PET in healthy subjects using statistical parametric mapping.

It is recognized that scatter correction can supply more accurate absolute quantification, and that iterative reconstruction results in better noise properties and significantly reduces streak artefacts; however, it is not entirely clear whether they produce significant changes in [18F]-FDG distribution of reconstructed 3D brain PET images relative to not scatter corrected images and analytic r...

متن کامل

Comparison of HRRT and HR+ Scanners

Purpose: To directly compare HRRT (high resolution brain) and HR+ (standard wholebody) PET only scanners for quantitative brain studies using three tracers with vastly different tracer distributions. Procedures: Healthy volunteers underwent successive scans on HR+ and HRRT scanners (in random order) using either (R)-[C]verapamil (n=6), [C]raclopride (n=7) or [C]flumazenil (n=7). For all tracers...

متن کامل

In vivo validation of reconstruction-based resolution recovery for human brain studies.

The aim of this study was to validate in vivo the accuracy of a reconstruction-based partial volume correction (PVC), which takes into account the point spread function of the imaging system. The NEMA NU2 Image Quality phantom and five healthy volunteers (using [(11)C]flumazenil) were scanned on both HR+ and high-resolution research tomograph (HRRT) scanners. HR+ data were reconstructed using n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 56 15  شماره 

صفحات  -

تاریخ انتشار 2011