Central venous catheter-related complications in children with oncological/hematological diseases: an observational study of 418 devices.
نویسندگان
چکیده
BACKGROUND The use of indwelling central venous catheters (CVCs) has become commonplace in the management of children undergoing anticancer treatment. Several types of CVC are available, while information on complications observed in children is scarce. We describe the experience of two tertiary care centers in Italy that prospectively followed up three types of CVC used at both institutions over a 30-month period. PATIENTS AND METHODS Between January 2000 and May 2002, double-lumen (DL) or single-lumen (SL) Hickman-Broviac (HB) catheters, and single-lumen pressure-activated safety valve (PASV) catheters were used and prospectively evaluated. Four types of possible complication were defined a priori: mechanical, thrombotic, malfunctioning and infectious. RESULTS Four hundred and eighteen CVCs (180 SL-HB, 162 DL-HB and 76 PASV) were inserted in 368 children, for a total of 107 012 catheter days at risk of complication. At least one complication occurred while using 169 of the devices (40%): 46% of the DL-HB, 46% of the PASV and 33% of the SL-HB (P=0.02) catheters. Subjects with hematological malignancies or non-malignant diseases had significantly more complications than those with solid tumors (P <0.0001). Overall, 234 complications were documented: 93 infectious [complication rate per 1000 catheter days at risk (CR)=0.87], 84 malfunctioning (CR=0.78), 48 mechanical (CR=0.45) and nine thrombotic (CR=0.08). SL-HB had statistically fewer infectious complications, while PASV had more mechanical complications. In a multivariate regression model, the most significant risk factors for having a CVC complication were hematological disease [relative risk (RR)=3.0; 95% confidence interval (CI) 1.8-4.8] and age <6 years at CVC insertion (RR=2.5; 95% CI 1.5-4.1). As for the type of CVC, compared with SL-HB, the DL-HB catheter had a statistically significant two-fold increased risk of any complication (RR=2.1; 95% CI 1.2-3.6), while the PASV catheter had a borderline RR of 1.8 (95% CI 1.0-3.6). Analysis by tumor type showed a higher risk of any kind of complication in patients with solid malignancies who had received a DL-HB catheter as compared with an SL-HB catheter (RR=7.2; 95% CI 2.8-18.7). CONCLUSIONS CVCs may cause complications in up to 40% of patients, with type of CVC, underlying disease and patient age being the three main factors that affect the incidence of CVC-related complications. SL-HB catheters have the best performance.
منابع مشابه
Effectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer
Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...
متن کاملCohort Study: Central Venous Catheter-Related Complications in Children with Hematologic Diseases at a Single Center
OBJECTIVE This study aims to document and analyze the central venous catheter (CVC)-related complications in children with hematological diseases who were treated within a single institution. MATERIALS AND METHODS A retrospective investigation was conducted in 106 pediatric patients in whom 203 CVCs were inserted. A total of 175 catheter-related complications occurred in 5 years. RESULTS Th...
متن کاملImplantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study
Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important. ...
متن کاملSkin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections
Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...
متن کاملTotally implantable central venous access devices in children with hemato-oncologic malignancies: evaluation of complications and comparison of incidence of febrile episodes with similar patients without central venous access devices.
The incidence of mechanical and infectious complications of totally implantable central venous access devices (TIDs) must be related to underlying disease, intensity of the chemotherapy, and frequency of manipulations. Records of the patients hospitalized from January 2002 to May 2005 were evaluated. Patients with TIDs were matched with patients without TIDs having the same malignancy and the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of oncology : official journal of the European Society for Medical Oncology
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2005