Plasma Levels of MicroRNA-155 Are Upregulated with Long-Term Left Ventricular Assist Device Support

نویسندگان

  • Teresa Wang
  • Emily C. O’Brien
  • Joseph G. Rogers
  • Daniel L. Jacoby
  • Michael E. Chen
  • Jeffrey M. Testani
  • Dawn E. Bowles
  • Carmelo A. Milano
  • G. Michael Felker
  • Chetan B. Patel
  • Pramod N. Bonde
  • Tariq Ahmad
چکیده

Left ventricular assist device (LVAD) therapy unloads the failing heart but exposes the human body to unique pathophysiologic demands such as continuous blood flow and complete univentricular support, which are associated with increased risk of adverse clinical outcomes. MicroRNAs (miRNAs) are 22-23 nucleotide RNAs involved in regulation of multiple biologic processes including the pathogenesis of heart failure (HF). Thus, measurement of miRNAs may have potential in both diagnostics as circulating biomarkers and in therapeutics for targeted interventions. We examined 23 distinct miRNAs that have previously been shown to play a role in HF pathogenesis and measured them in 40 individuals both before continuous-flow LVAD implantation and at a median of 96.5 days after implantation. Quantitative real-time polymerase chain reaction was performed for miRNA amplification, and 19 miRs were included in statistical analysis. Wilcoxon signed-rank tests were used to compare within-patient median relative quantification values pre- and post-LVAD placement. The median age of patients was 67 years, and 57.5% were at Interagency Registry for Mechanically Assisted Circulatory Support level 1-2. After LVAD support, only miR-155 was found to be statistically significant (p < 0.002), with an upregulation in plasma expression levels with LVAD support, which persisted regardless of the direction of change in serial HF biomarker levels. MicroRNA-155, which has been shown to play a central role in inflammation and neovascularization, was upregulated with long-term LVAD support. If validated by future studies, miR-155 may help further inform on underlying LVAD physiology and has a role as a therapeutic target in this patient population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods.

Continuing in vivo trials are being conducted at the University of Pittsburgh using the Nimbus axial flow blood pump (AxiPump). To date, 14 sheep experiments have been performed to address several issues related to short-term support. Six acute experiments (< 6 hr) have been performed to assess hemodynamics related to speed regulation and to determine anatomic placement of the pump and cannulae...

متن کامل

Late Complications Following Continuous-Flow Left Ventricular Assist Device Implantation

Left ventricular assist devices have become standard therapy for patients with end-stage heart failure. They represent potential long-term solutions for a growing public health problem. However, initial enthusiasm for this technology has been tempered by challenges posed by long-term support. This review examines these challenges and out current understanding of their etiologies.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 63  شماره 

صفحات  -

تاریخ انتشار 2017