Highly accelerated dynamic contrast enhanced imaging.

نویسندگان

  • Robert Marc Lebel
  • Jesse Jones
  • Jean-Christophe Ferre
  • Meng Law
  • Krishna S Nayak
چکیده

PURPOSE Dynamic contrast-enhanced imaging provides unique physiological information, notably the endothelial permeability (K(trans)), and may improve the diagnosis and management of multiple pathologies. Current acquisition methods provide limited spatial-temporal resolution and field-of-view, often preventing characterization of the entire pathology and precluding measurement of the arterial input function. We present a method for highly accelerated dynamic imaging and demonstrate its utility for dynamic contrast-enhanced modeling. METHODS We propose a novel Poisson ellipsoid sampling scheme and enforce multiple spatial and temporal l1-norm constraints during image reconstruction. Retrospective and prospective analyses were performed to validate the approach. RESULTS Retrospectively, no mean bias or diverging trend was observed as the acceleration rate was increased from 3× to 18×; less than 10% error was measured in K(trans) at any individual rates in this range. Prospectively accelerated images at a rate of 36× enabled full brain coverage with 0.94 × 0.94 × 1.9 mm(3) spatial and 4.1 s temporal resolutions. Images showed no visible degradation and provided accurate K(trans) values when compared to a clinical population. CONCLUSION Highly accelerated dynamic MRI using compressed sensing and parallel imaging provides accurate permeability modeling and enables full brain, high resolution acquisitions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Highly Accelerated 3d Dynamic Contrast Enhanced Mri Using Partial Separability Model and Jsense

PURPOSE: Dynamic contrast enhanced (DCE) MRI requires high spatial resolution for morphological information and high temporal resolution for contrast pharmacokinetic modeling. The current fast imaging techniques [1-5] have shown success in improving the temporal resolution of DCE-MRI. However, it is still challenging to improve both the spatial and temporal resolutions simultaneously. This abst...

متن کامل

Highly accelerated dynamic contrast enhanced imaging with prospective undersampling

Introduction: Dynamic contrast enhanced (DCE) imaging employs serial T1-weighted scans to quantify the pharmacokinetics of an injectable contrast agent. This allows assessment of tissue properties such as vascular permeability. Clinical applications of DCE, such as tumor characterization, will benefit from improvements in spatiotemporal resolution and volume coverage beyond what is possible tod...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2014