Cmm Probe Testing by Means of a Low Force Sensor
نویسندگان
چکیده
Abstract: The method and the computerised set-up for the accuracy of touch trigger probe testing, outside CMM is discussed. A high resolution interference displacement transducer with a low measuring force is applied. The results of preliminary tests of TP2-5W and TP6 (Renishaw) probe in XYZ space are shown. The metrological characteristics of the probe are analysed.
منابع مشابه
Design and Construction of a New Capacitive Tactile Sensor for Measuring Normal Tactile Force
This paper presents the design, construction and testing of a new capacitive tactile sensor for measurement of normal tactile force. The operation of proposed sensor has been investigated in ASTABLE and MONOSTABLE circuits. According to the results of these circuits the deviation of ASTABLE circuit results is less than MONOSTABLE circuit results. In addition, the results obtained from ASTABLE c...
متن کاملSpatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy
The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...
متن کاملA Unique Sensor Fusion System for Coordinate Measuring Machine Tasks
This paper describes a real-time hierarchical system that combines (fuses) data from vision and touch sensors to simplify and improve the operation of a coordinate measuring machine (CMM) used for dimensional inspection tasks. Our emphasis is on sensory processing techniques that can aid CMM applications rather than on the analysis of CMM performance measurements. Our system consists of sensory...
متن کاملTip sensor probe for changing refractive index measurement in small volumes
In this paper, a tapered tip optical fiber probe sensor for localized refractive index (RI) measurements is presented. This sensor’s interaction with analytes is confined to a few micro-meters which makes it a promising candidate for in-vivo or even intra-cellular RI monitoring. This tapered tip was simply fabricated by etching optical fiber with hydrofluoric acid to a conic shape with a sub-m...
متن کاملThe Effect of Input Shaping on Coordinate Measuring Machine Repeatability
Coordinate Measuring Machines (CMMs) are a strategic element in the manufacture of high-precision parts because their measurements of part geometries are used for quality control and feedback on the manufacturing process. Proper CMM operation requires accurate knowledge of the position of the CMM's part sensor. The performance of a CMM is limited by background vibration levels, environmental co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -