In vivo 31P-MRS at 7T by single voxel E-ISIS with GOIA selection pulses
نویسندگان
چکیده
The GOIA-HS(8,4) pulses used for ISIS localisation offered excellent slice profiles with high bandwidth (20-40kHz) similar to FOCI but at lower B1 (Fig.2) or shorter pulses (~3 ms) even in 5 cm distance to the surface coil. Large selective gradients (25mT/m) reduced the CSDE to ±1.4mm for the most important metabolites (PME to γ-ATP) independent of voxel size. Contamination tests with TR~1.2T1 revealed ~10-15% contamination for combination of ISIS+rectangular excitation, ~7-9% contamination for ISIS+BIR-4, and ~2-3% contamination for ISIS+BIR-4+E-ISIS schema. High spectral quality was achieved in vivo for small voxel sizes (2.5cm iso) in only 3:48 min measurement time. (Fig. 3) Reproducibility measurements underline the reliability of the spectral quantification of in vivo muscle spectra. The determined metabolite ratios were (mean±SD) 0.13±0.02 for Pi/PCr, 0.06±0.01 for PDE/PCr, 0.23±0.02 for γ-ATP/PCr, 0.25±0.02 for α-ATP/PCr, and 0.12±0.01 for β-ATP/PCr. In vivo 31P-MRS at 7T by single voxel E-ISIS with GOIA selection pulses
منابع مشابه
Gradient offset independent adiabatic pulses for high-field MR spectroscopy on clinical scanners
Adiabatic pulses are necessary to mitigate chemical shift artifact (CSA) and rf inhomogeneity at high-field MRS, but often they need longer durations (≥ 5 ms) and higher rf strengths (> 1 kHz) that limits their application in-vivo. Gradient offset independent adiabatic (GOIA) pulses have been proposed [1] as an elegant solution to reduce these requirements while effectively increasing the excit...
متن کاملImplementation of GOIA-Wurst pulse in a SPECIAL localization sequence at 7T
Introduction In H MR spectroscopy the SPin ECho, full Intensity Acquired Localized (SPECIAL) acquisition sequence combines the advantages of ultra-short echo times (TE) with full sensitivity obtained by Spin Echo (SE) based sequences [1,2]. In particular, J-coupled multiplets and metabolites with short T2 relaxation times benefit from an improved SNR at the short TEs, which are in the order of ...
متن کاملArtefact minimized spectral editing at 7T: quick and accurate in-vivo detection of GABA
Introduction: Spectral editing techniques are used in MRS to improve the detection of low concentrated metabolites like GABA [1], of which signals are overlapped with resonances of other highly concentrated compounds, such as Creatine and macromolecules. However, these methods rely on subtraction of two in vivo MR spectra and, therefore, are prone to artefacts. MRS at high field benefits from h...
متن کاملSPECIAL-COSY at 7T
Introduction Metabolites of particular interest are neurotransmitters and their precursors such as glutamine (Gln), glutamate (Glu), N-acetyl-aspartyl-glutamate (NAAG) and gamma amino butyric acid (GABA), as well as antioxidants such as glutathione (GSH) and ascorbic acid (Asc / vitamin C), whose important roles in the pathophysiology of neurological and psychiatric disorders is still not fully...
متن کاملT1 and T2 Metabolite Relaxation Times in Normal Brain at 3T and 7T
Proton magnetic resonance spectroscopy (MRS) is a powerful noninvasive tool that has been widely used for the assessment of brain metabolites and the investigation of normal and abnormal metabolism in brain tissue. With the availability of improved hardware and acquisition techniques, in vivo single-voxel 1H-MRS and multivoxel magnetic resonance spectroscopic imaging (MRSI) can offer new possib...
متن کاملذخیره در منابع من