Multilayer-film analysis for urea nitrogen in blood, serum, or plasma.

نویسندگان

  • A Ohkubo
  • S Kamei
  • M Yamanaka
  • H Katsuyama
  • Y Iwata
  • N Sekikawa
چکیده

Two types of multilayer-film slides for measurement of urea nitrogen in blood are reported here: one for whole-blood samples, the other for plasma or serum. Urea nitrogen concentrations in plasma are determined almost immediately, without preparation of reagents or centrifugation of blood samples. Because the sample volume applied to the slide is not critical, reliable results are quickly obtained by the neophyte.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The multilayered film analyzer: glucose in serum, plasma, cerebrospinal fluid, and urine; and urea nitrogen in serum and plasma.

Some basic laboratory performance criteria were studied for the Eastman Kodak glucose and urea nitrogen analyzer. Serum, plasma, urine, and cerebrospinal fluid were tested. Precision, both "within-day" and "between-day," for both analytes was less than 2.2% (CV). Both analytes demonstrated linearity, with about 100% recovery of added substrates. Comparisons with continuous-flow procedures demon...

متن کامل

Extended clinical trial and evaluation of urea nitrogen determination with the Ektachem GLU/BUN analyzer.

We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analysis for urea nitrogen with the multilayer film analysis system ("Ektachem"). We analyzed 456 clinical samples with this instrument, by the manual urease/glucose dehydrogenase method, and with the Beckman System I GLU/BUN An...

متن کامل

Evaluation of the effect of exercise on serum creatinine and urea nitrogen in hemodialysis patients

Introduction. Chronic renal failure is a progressive disease in which kidney function is impaired, so that the body can not metabolize and maintain fluid balance and electrolytes. Therefore, the present study investigated changes in serum creatinine and urea nitrogen in hemodialysis patients in response to exercise. Materials and Methods. The subjects of this study were dialysis patients who we...

متن کامل

Association between Plasma and Milk Urea on the Insemination Day and Pregnancy Rate in Early Lactation Dairy Cows

Lactatingdairy cows (n=177) fed with grass and corn silage ad libitum kept in pasture, were randomly assigned to evaluate how urea nitrogen in plasma and milk can be related to their pregnancy rate. Blood and milk samples were collected on the artificial insemination (AI) day to evaluate plasma urea nitrogen (PUN) and milk urea nitrogen (MUN) as well as progesterone levels, excluding cows with ...

متن کامل

Multilayer film elements for clinical analysis: applications to representative chemical determinations.

Using the general concept of a dry multilayer analytical element, we can change chemical procedures and configurations to assay several blood components. In the assay of serum urea nitrogen, urease in the reagent layer catalyzes the hydrolysis of urea. A semipermeable membrane excludes aqueous base, but allows ammonia to diffuse to an underlying indicator layer. For the amylase determination, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 1984