Reflective oxygen saturation monitoring at hypothenar and its validation by human hypoxia experiment
نویسندگان
چکیده
BACKGROUND Pulse oxygen saturation (SpO2) is an important parameter for healthcare, and wearable sensors and systems for SpO2 monitoring have become increasingly popular. The aim of this paper is to develop a novel SpO2 monitoring system, which detects photoplethysmographic (PPG) signals at hypothenar with a reflection-mode sensor embedded into a glove. METHODS A special photo-detector section was designed with two photodiodes arranged symmetrically to the red and infrared light-emitting diodes (LED) to enhance the signal quality. The reflective sensor was placed in a soft silicon substrate sewn in a glove to fit the surface of the hypothenar. To lower the power consumption, the LED driving current was reduced and energy-efficient electronic components were applied. The performance for PPG signal detection and SpO2 monitoring was evaluated by human hypoxia experiments. Accelerometer-based adaptive noise cancellation (ANC) methods applying the least mean squares (LMS) and recursive least squares (RLS) algorithms were studied to suppress motion artifact. RESULTS A total of 20 subjects participated in the hypoxia experiment. The degree of comfort for wearing this system was accepted by them. The PPG signals were detected effectively at SpO2 levels from about 100-70%. The experiment validated the accuracy of the system was 2.34%, compared to the invasive measurements. Both the LMS and RLS algorithms improved the performance during motion. The total current consumed by the system was only 8 mA. CONCLUSIONS It is feasible to detect PPG signal and monitor SpO2 at the location of hypothenar. This novel system can achieve reliable SpO2 measurements at different SpO2 levels and on different individuals. The system is light-weighted, easy to wear and power-saving. It has the potential to be a solution for wearable monitoring, although more work should be conducted to improve the motion-resistant performance significantly.
منابع مشابه
Human activated macrophages and hypoxia: a comprehensive review of the literature
Macrophages accumulate in poorly vascularised and hypoxic sites including solid tumours, wounds and sites of infection and inflammation where they can be exposed to low levels of oxygen for long periods. Up to date, different studies have shown that a number of transcription factors are activated by hypoxia which in turn activate a broad array of mitogenic, pro-invasive, pro-angiogenic, and pro...
متن کاملThe effect of hypoxia on visual function
The effect vqf the inspiration of a mixture of 10 per cent oxygen and 90 per cent nitrogen on several aspects of dark adaptation was studied in three highly trained observers. Arterial oxygen saturations were monitored during all experiments. The necessity of using highly trained subjects and particularly of monitoring arterial oxygen saturations in such studies was emphasized. Hyperventilation...
متن کاملCerebral oxygenation during hypoxia and resuscitation by using near-infrared spectroscopy in newborn piglets.
BACKGROUND Hypoxic events and cardiac arrest may cause brain damage in critical infants. This study investigated cerebral tissue oxygenation and oxygen extraction in a piglet model of hypoxic events, cardiac arrest and effects of resuscitation. METHODS For the hypoxia experiment, anesthetized newborn piglets were randomized to a hypoxia group (n = 8) with decreasing ventilatory rate to 0, and...
متن کاملValidation of pulse oximetry during progressive normobaric hypoxia utilizing a portable chamber.
Validation of pulse oximetry in commercially available normobaric hypoxic chambers (NHC) has not been previously reported. The present study examined the validity of pulse oximetry (SpO2) against direct measurements of arterial oxygen saturation (SaO2) via co-oximetry (AVOXimeter 4000) in 13 young adults age 21.3 +/- 0.6 years. Over a period of 2.5 hrs, the inspired fraction of oxygen inside a ...
متن کاملBrain monitoring in neonates.
Continuous EEG monitoring with amplitude-integrated electroencephalography (aEEG) has become a part of the routine neurological care in the neonatal unit, especially in full-term infants with hypoxia-ischemia and in infants suspected of seizures. Its prognostic value after birth asphyxia is well established and seizure detection has improved with the new digital aEEG devices with access to the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2015