Use of molecular and reference susceptibility testing methods in a multicenter evaluation of MicroScan dried overnight gram-positive MIC panels for detection of vancomycin and high-level aminoglycoside resistances in enterococci.

نویسندگان

  • Y S Chen
  • S A Marshall
  • P L Winokur
  • S L Coffman
  • W W Wilke
  • P R Murray
  • C A Spiegel
  • M A Pfaller
  • G V Doern
  • R N Jones
چکیده

Modified MicroScan gram-positive MIC no. 8 panels (PM-8) were analyzed for their improved ability to detect vancomycin resistance (VR) and high-level aminoglycoside resistance (HLAR) in enterococci. A validation study design that utilized selected challenge strains, recent clinical isolates, and reproducibility experiments in a multicenter format was selected. Three independent medical centers compared the commercial panels to reference broth microdilution panels (RBM) and Synergy Quad Agar (QA). Resistance was verified by demonstration of VR and HLAR genes by PCR tests. The study was conducted in three phases. (i) In the challenge phase (CP), two well-characterized sets of enterococci were obtained from the Centers for Disease Control and Prevention; one set contained 50 isolates for VR testing and one contained 48 isolates for HLAR testing. In addition, a set of 47 well-characterized isolates representing diverse geographic areas, obtained from earlier national surveillance studies, was tested at the University of Iowa College of Medicine (UICM). (ii) In the efficacy phase (EP), each laboratory tested 50 recent, unique clinical isolates by all methods. (iii) In the reproducibility Phase (RP), each laboratory tested the same 10 strains by all methods in triplicate on three separate days. All isolates from the EP were sent to the UICM for molecular characterization of vanA, -B, -C1, -C2-3, and HLAR genes. In the CP, the ranking of test methods by error rates (in parentheses; very major and major errors combined, versus PCR results) were as follows: for high-level streptomycin resistance (HLSR), QA (12.0%) > PM-8 (5.2%) > RBM (1.6%); for high-level gentamicin resistance (HLGR), RBM (3.7%) > PM-8 (3.1%) > QA (2.6%); and for VR, RBM = QA (3.0%) > PM-8 (1.2%). In the EP, agreement between all methods and the reference PCR result was 98.0% for HLSR, 99.3% for HLGR, and 98. 6% for VR. In the RP, the percentages of results +/- 1 log2 dilution of the all-participant mode were as follows: for VR, 100% (PM-8), 98.9% (QA), and 90.0% (RBM); for HLSR, 99.6% (RBM), 98.5% (PM-8), and 82.2% (QA); and for HLGR, 99.6% (RBM), 99.3% (PM-8), and 98.1% (QA). The ability of the PM-8 to detect VR and HLAR in enterococci was comparable to those for reference susceptibility and molecular PCR methods and was considered acceptable for routine clinical laboratory use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels.

Studies were conducted on a method of direct inoculation of MicroScan dried overnight and of rapid panels with positive aerobic blood cultures obtained from the BacT/Alert to determine antimicrobial susceptibilities. Inocula were limited to specimens that appeared unimicrobic on Gram stain. Results were compared to those obtained from panels inoculated following subculture. For 133 gram-negativ...

متن کامل

Evaluation of drug sensitivity of Entrococcus faecium and Entrococcus faecalis Strains and Detection of VanA/B Genes in Vancomycin Resistance Isolated by PCR Method

Enterococci, as the major cause of nosocomial infections, have been shown to have an increase in drug resistance during the past two decades. TheEntrococcalemergence of Vancomycin-resistant is very important nowadays. The purpose of this study was to determine the drug sensitivity of Enterococcus faecalis and Enterococcus faecium species against Vancomycin, Tetracycline, Gentamicin, Erythromyci...

متن کامل

Detection of enterococcal high-level aminoglycoside resistance with MicroScan freeze-dried panels containing newly modified medium and Vitek Gram-Positive Susceptibility cards.

Both conventional and modified MicroScan Type 5 panels and Vitek Gram-Positive Susceptibility cards were compared with agar dilution screen plates for their abilities to detect high-level resistance to gentamicin and streptomycin in 235 enterococcal isolates, including 167 Enterococcus faecalis and 63 E. faecium isolates. The modified Type 5 panels contained dextrose-phosphate broth instead of ...

متن کامل

Clinical importance of identifying coagulase-negative staphylococci isolated from blood cultures: evaluation of MicroScan Rapid and Dried Overnight Gram-Positive panels versus a conventional reference method.

We evaluated the clinical usefulness of species identification of blood isolates of coagulase-negative staphylococci as a predictor of the clinical significance of the isolates. In addition, we compared results of species identification obtained with MicroScan Rapid Gram-Positive Identification panels and Dried Overnight (Conventional) Gram-Positive Identification panels with those obtained by ...

متن کامل

Reliability of Disk Diffusion Test Results for the Antimicrobial Susceptibility Testing of Nosocomial Gram-positive Microorganisms: Is E-test Method Better?

   Disk diffusion test is the usual applicable method for assessing the antimicrobial susceptibility pattern in most institutions and hospitals. The aim of this study was to determine the reliability of resistant-reported results of disk diffusion test for 6 routinely used antibiotics against Gram-positive microorganisms of nosocomial origin, using E-test method.    Over a 1-year period, clinic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 1998