Blind source separation analysis of PET dynamic data: a simple method with exciting MR-PET applications

نویسندگان

  • Ana-Maria Oros-Peusquens
  • Nuno da Silva
  • Carolin Weiss
  • Gabrielle Stoffels
  • Hans Herzog
  • Karl J Langen
  • N Jon Shah
چکیده

Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, 52425 Jülich, Germany Denoising of dynamic PET data improves parameter imaging by PET and is gaining momentum. This contribution describes an analysis of dynamic PET data by blind source separation methods and comparison of the results with MR-based brain properties. Five glioblastoma patients underwent a 1-hr simultaneous MRI and dynamic FET PET measurement as part of preoperative evaluation and planning of brain surgery. The MRI protocol included T1-weighted scans acquired before and after contrast agent administration, highlighting the vasculature network and blood-brain barrier breakdown, as well as a T2-weighted scan for oedema visualization and segmentation. The PET data were binned into 18 consecutive time points and time activity curves of FET uptake were generated. For the analysis of dynamic PET data, we assumed there are a set of independent sources in the data and used the algorithm svd implemented in Matlab for decomposition. The time activity curves for each source/component were investigated; images representing the components were obtained. The analysis was performed separately on tissue affected by the tumour and on ‘normal tissue’ (complementary of tumour region). Results obtained on the whole brain and on ‘normal tissue’ were very similar and very similar between patients. The TACs obtained from tissue affected by the tumour (mask defined from SPACE data) were different from those of normal tissue and showed greater variability between patients. The TAC of component(2) was found to be suggestive of vasculature behavior. This was confirmed by the spatial correspondence between component(2) and the vascular network identified by MRI (from preand post-contrast MPRAGE). The effect of denoising on PET data and on the TACs was found to be substantial. By this method, brain networks can be investigated in (denoised) dynamic data obtained with any PET tracer. For their further identification, comparison with highresolution MRI data is crucial. Oros-Peusquens et al. EJNMMI Physics 2014, 1(Suppl 1):A28 http://www.ejnmmiphys.com/content/1/S1/A28

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of input function from dynamic PET brain data using Bayesian blind source separation

Selection of regions of interest in an image sequence is a typical prerequisite step for estimation of time-activity curves in dynamic positron emission tomography (PET). This procedure is done manually by a human operator and therefore suffers from subjective errors. Another such problem is to estimate the input function. It can be measured from arterial blood or it can be searched for a vascu...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

PET/MR: a paradigm shift

More than a decade ago, multimodality imaging was introduced into clinical routine with the development of the positron emission tomography (PET)/computed tomography (CT) technique. Since then, PET/CT has been widely accepted in clinical imaging and has emerged as one of the main cancer imaging modalities. With the recent development of combined PET/magnetic resonance (MR) systems for clinical ...

متن کامل

Production and quality control of 66Ga as a PET radioisotope

Background: 66Ga (t1/2=9.49 h, β+: 4.153 MeV, γ: 511, 834, 1039, 2752 keV) has a wide range of applications in different fields of medical sciences. Production of 66Ga became one of our main interests, according to its increasing applications in nuclear medicine, particularly in PET imaging. Materials and Methods: 66 Zn (p,n)66Ga reaction was determined as the best choice for the production of ...

متن کامل

Dynamic analysis of MR-PET data on brain tumors

Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Portugal The introduction of hybrid MR-PET scanners offers new perspectives to better correlate MR and PET data with respect to time and space domain. In case of brain tumor patients, dynamic susceptibility contrast (DSC)-MRI is often used to measure perfusion levels of brain, while dynamic [F]-fluoro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014