Improved resolution in the detection of oligonucleotides up to 60-mers in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using pulsed-delayed extraction with a simple high voltage transistor switch.
نویسندگان
چکیده
Pulsed-delayed extraction using a simple high voltage transistor switch together with various sample purification approaches were used to enhance the resolution in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of oligonucleotides up to 60 bases long. This switch can provide a 0-3 kV voltage pulse with a 75 ns fall time. A resolution of 500-900 was typically observed for samples from 5-mers to 60-mers using pulsed-delayed extraction (PDE) with the switch described herein. The resolution deteriorated to < 100 for oligonucleotides of > or = 65-mers. With the TOF acceleration region configuration used in this work, the resolution was found not to vary significantly over a delay range of 2-5 mus. As the DNA size increased to over 35-mer, HPLC purification was required to retain the enhancement in resolution provided by PDE MALDI-MS.
منابع مشابه
5-Methoxysalicylic acid and spermine: a new matrix for the matrix-assisted laser desorption/ionization mass spectrometry analysis of oligonucleotides.
5-Methoxysalicylic acid (MSA) is demonstrated to be a useful matrix for matrix-assisted laser desorption/ionization time-of-flight (TOF) mass spectrometry of oligonucleotides, when desorption/ionization without fragmentation is desired. When MSA is combined with the additive spermine, the need for desalting is reduced. The MSA/spermine matrix yields linear TOF mass spectra with improved resolut...
متن کاملA matrix of 3,4-diaminobenzophenone for the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
A new matrix of 3,4-diaminobenzophenone (DABP) was demonstrated to be advantageous in the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. With DABP as a matrix, intact oligonucleotide ions can be readily produced with lower laser powers, resulting in better detection limits, less fragmentation and fewer alkali metal ion adducts compa...
متن کاملMatrix-assisted laser desorption ionization time-of-flight mass spectrometry: a powerful tool for the mass and sequence analysis of natural and modified oligonucleotides.
We report the analysis and characterization of natural and modified oligonucleotides by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). The present technology was highly improved for this class of compounds by using a new matrix, 2,4,6-trihydroxy acetophenone, together with di- and triammonium salts of organic or inorganic acids to suppress peak broa...
متن کاملC60 secondary ion mass spectrometry with a hybrid-quadrupole orthogonal time-of-flight mass spectrometer.
A hybrid quadrupole orthogonal time-of-flight mass spectrometer optimized for matrix-assisted laser desorption ionization (MALDI) and electrospray ionization has been equipped with a C 60 cluster ion source. This configuration is shown to exhibit a number of characteristics that improve the performance of traditional time-of-flight secondary ion mass spectrometry (TOF-SIMS) experiments for the ...
متن کاملAccurate mass measurement of DNA oligonucleotide ions using high-resolution time-of-flight mass spectrometry.
Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 11 9 شماره
صفحات -
تاریخ انتشار 1997