An Official Journal of the American Heart Association Application of a Constant Indicator Dilution Method to the Measurement of Local Venous Flow
نویسنده
چکیده
• Many investigations of the cardiovascular system require estimations of regional or single vessel blood flow. Although direct methods ' have been devised for this purpose, most have a limited application in man because they involve exposure of the appropriate blood vessel. When multiple and frequent flow estimations over a long period are desired in experimental animals, repeated exposures of the same vessel or region may present difficulties. Hence, a technique that would eliminate this procedure would be of value. Although indicator dilution methods have been used to estimate regional or single vessel blood flow in man and experimental animals, certain problems in their application have emerged. Andres et al. measured human brachial artery flow, Peterson et al. left ventricular output, and Grace et al. thoracic aortic flow by injecting Evans blue dye at a constant rate into the artery and recording a dilution curve from an accompanying vein or
منابع مشابه
The measurement of segmental venous flow by an indicator dilution method.
Several methods have been evolved for the measurement of venous flow in animals, but most have a limited application in man as they involve exposure of the appropriate blood vessel. These methods include the Ludwig type stromuhr (Tigerstedt, 1892), the thermostrontuhr (Rein, 1928; Schmidt and Walker, 1935; Shipley et al., 1942), the bubble flow meter (Soskin et al., 1934; Brunner, 1948), the di...
متن کاملApplication of a Constant Indicator Dilution Method to the Measurement of Local Venous Flow.
• Many investigations of the cardiovascular system require estimations of regional or single vessel blood flow. Although direct methods ' have been devised for this purpose, most have a limited application in man because they involve exposure of the appropriate blood vessel. When multiple and frequent flow estimations over a long period are desired in experimental animals, repeated exposures of...
متن کاملUse of a local indicator dilution technique for the measurement of oscillatory flow.
An indicator dilution method for measuring oscillatory flow in a vessel is analyzed in terms of a mixing chamber with a constant volume. For the correct measurement of mean flow, the time constant of detection of the indicator Should be very much shorter than the shortest time constant of the mixing volume. The performance of such a system was examined with a thermal indicator. Although the app...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملApplication of Boundera Element Method (Bem) to Two-Dimensional Poisson's Eqation
BEM can be used to solve Poisson's equation if the right hand side of the equation is constant because it can easily be transformed to an equivalent Laplace equation. However, if the right hand side is not constant, then such a treatment is impossible and part of the equation can not be transformed over the boundary, hence, the whole domain has to be discretized. Although this takes away impor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005