Synchrotron Radiation for On-chip Mid-ir Detection at the Diffraction Limit
نویسندگان
چکیده
Microchips for rapid mixing of two aqueous streams have been produced using CaF2 wafers and SU-8 microstructuring technology and tested at the IR beamline of Bessy II in Berlin, Germany. Advantage of the synchrotron radiation over thermal globar sources for measuring at sample spots close to the diffraction limit of the employed mid-IR radiation have been documented. The capability of the experimental set-up to initiate and monitor chemical reactions label-free in pL volumina was verified. Simple chemical reactions such as titration of acetic acid and conformational change of the protein β2-microglobulin have been recorded.
منابع مشابه
Mid-IR synchrotron radiation for molecular specific detection in microchip-based analysis systems.
Microstructures constructed from SU-8 polymer and produced on CaF(2) base plates have been developed for microchip-based analysis systems used to perform FTIR spectroscopic detection using mid-IR synchrotron radiation. The high brilliance of the synchrotron source enables measurements at spot sizes at the diffraction limit of mid-IR radiation. This corresponds to a spatial resolution of a few m...
متن کاملSpatial resolution limits for synchrotron-based spectromicroscopy in the mid- and near-infrared.
Spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source in Berkeley, CA, USA, a third-generation synchrotron light source. This beamline couples the high-brightness synchrotron source to a Thermo-Electron Continumicrom XL infrared microscope. Two types of resolution tests were performed in both the mid-IR and near-IR. The results are compared with a diffraction-li...
متن کاملDetection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study
Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...
متن کاملSpatial resolution limits for synchrotron-based infrared spectromicroscopy
Detailed spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source synchrotron facility in Berkeley, CA. The high-brightness synchrotron source is coupled at this beamline to a Thermo-Electron ContinulmXL infrared microscope. Two types of resolution tests in both the mid-IR (using a KBr beamsplitter and an MCT-A* detector) and in the near-IR (using a CaF2 beamsplitt...
متن کاملA Review of the Applications of Synchrotron Radiation in Archaeological Sciences
The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004