Binocular open-view system to perform estimations of aberrations and scattering in the human eye.

نویسندگان

  • Carlos E García-Guerra
  • Mikel Aldaba
  • Montserrat Arjona
  • Jaume Pujol
چکیده

We present a system that integrates a double-pass (DP) instrument and a Hartmann-Shack (HS) wavefront sensor to provide information not only on aberrations, but also on the scattering that occurs in the human eye. A binocular open-view design permits evaluations to be made under normal viewing conditions. Furthermore, the system is able to compensate for both the spherical and astigmatic refractive errors that occur during measurements by using devices with configurable optical power. The DP and HS techniques provide comparable data after estimating wavefront slopes with respect to the intersections of an ideal grid and compensating for residual errors caused by the optical defects of the measuring system. Once comparable data is obtained, it is possible to use this combined manner of assessment to provide information on scattering. Measurements in an artificial eye suggest that the characteristics of the ocular fundus may induce deviations of DP with respect to the HS data. These differences were quantified in terms of the modulation transfer function in young, healthy eyes measured in infrared light to demonstrate the potential use of the system in visual optics studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peep Into Visual Acuity Chart Through an Opening: A New Concept of Binocular Open-view Visual Acuity Test.

To the Editor: For some time we have used a clinical visual acuity test (subjective refraction) only for monocular testing. However, we believe that visual acuity measurements need to be performed under binocular open-view conditions as close to natural viewing conditions as possible. Subjective refractions without cycloplegia were examined with the Occlupad (Japan Focus Co., Ltd., Tokyo, Japan...

متن کامل

Temporal dynamics of ocular aberrations: monocular vs binocular vision.

The temporal dynamics of ocular aberrations are important for the evaluation of, e.g. the accuracy of aberration estimates, the correlation to visual performance, and the requirements for real-time correction with adaptive optics. Traditionally, studies on the eye's dynamic behavior have been performed monocularly, which might have affected the results. In this study we measured aberrations and...

متن کامل

Night myopia is reduced in binocular vision.

Night myopia, which is a shift in refraction with light level, has been widely studied but still lacks a complete understanding. We used a new infrared open-view binocular Hartmann-Shack wave front sensor to quantify night myopia under monocular and natural binocular viewing conditions. Both eyes' accommodative response, aberrations, pupil diameter, and convergence were simultaneously measured ...

متن کامل

A Fast, Robust, Automatic Blink Detector

Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...

متن کامل

Objective Evaluation of Visual Fatigue Using Binocular Fusion Maintenance

Purpose In this study, we investigated whether an individual's visual fatigue can be evaluated objectively and quantitatively from their ability to maintain binocular fusion. Methods Binocular fusion maintenance (BFM) was measured using a custom-made binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters, wherein eye movements and wavefront aberrations ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 54 32  شماره 

صفحات  -

تاریخ انتشار 2015