Pseudo-outbreak of Legionella pneumophila serogroup 8 infection associated with a contaminated ice machine in a bronchoscopy suite.

نویسندگان

  • A N Schuetz
  • R L Hughes
  • R M Howard
  • T C Williams
  • F S Nolte
  • D Jackson
  • B S Ribner
چکیده

OBJECTIVE To investigate the marked increase noted over an 8-month period in the number of Legionella pneumophila isolates recovered from bronchoalveolar lavage fluid specimens obtained during bronchoscopy in our healthcare system. SETTING Bronchoscopy suite that serves a 580-bed tertiary care center and a large, multisite, faculty practice plan with approximately 2 million outpatient visits per year. METHODS Cultures of environmental specimens from the bronchoscopy suite were performed, including samples from the air and water filters, bronchoscopes, and the ice machine, with the aim of identifying Legionella species. Specimens were filtered and acid-treated and then inoculated on buffered charcoal yeast extract agar. Serogrouping was performed on all isolates recovered from patient and environmental samples. RESULTS All L. pneumophila isolates recovered from patients were serogroup 8, a serogroup that is not usually recovered in our facility. An epidemiologic investigation of the bronchoscopy suite revealed the ice machine to be contaminated with L. pneumophila serogroup 8. Patients were exposed to the organism as a result of a recently adopted practice in the bronchoscopy suite that involved directly immersing uncapped syringes of sterile saline in contaminated ice baths during the procedures. At least 1 patient was ill as a result of the pseudo-outbreak. Molecular typing of isolates recovered from patient and environmental samples revealed that the isolates were indistinguishable. CONCLUSIONS Extensive cleaning of the ice machine and replacement of the machine's water filter ended the pseudo-outbreak. This episode emphasizes the importance of using aseptic technique when performing invasive procedures, such as bronchoscopies. It also demonstrates the importance of reviewing procedures in all patient areas to ensure compliance with facility policies for providing a safe patient environment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Legionnaires' disease outbreak: a water blaster and roof-collected rainwater systems.

In February 2006, an outbreak of Legionnaires' disease (LD) was identified in Beachlands, a small, isolated east Auckland suburb. It was investigated through case finding, a case-control study, sampling potential sources of infection and by molecular typing (using sequence-based typing (SBT) of all Legionella pneumophila serogroup 1 (Lp1) isolates). Lp1 was isolated from the respiratory tract o...

متن کامل

Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...

متن کامل

Molecular typing of nosocomial isolates of Legionella pneumophila serogroup 3.

In Paris, France, an outbreak of pneumonia due to Legionella pneumophila serogroup 3 was observed in Necker (four cases) and Pitié (six cases) hospitals. Neither the 10 clinical isolates nor 5 tap water isolates from Necker Hospital harbored plasmids. Clinical and environmental serogroup 3 isolates and serogroup 3 reference strain Bloomington 2 were analyzed by chromosomal probe fingerprinting....

متن کامل

Complete Genome Sequences of Three Outbreak-Associated Legionella pneumophila Isolates

We report here the complete genome sequences of three Legionella pneumophila isolates that are associated with a Legionnaires' disease outbreak in New York in 2012. Two clinical isolates (D7630 and D7632) and one environmental isolate (D7631) were recovered from this outbreak. A single isolate-specific virulence gene was found in D7632. These isolates were included in a large study evaluating t...

متن کامل

Heterogeneity of antibody response in infection with Legionella pneumophila serogroup 1.

The antibody response of patients infected with Legionella pneumophila serogroup 1 in a common source outbreak was investigated. Heat-killed antigens from L pneumophila serogroups 1-3 and 6-10, plus several other strains of L pneumophila, together with 13 other species of legionellas were used in an indirect fluorescence antibody test. Formolised yolk sac antigens made from L pneumophila serogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 2009