Optical Measurement of Straylight in Eyes With Cataract.

نویسندگان

  • Onurcan Sahin
  • Alexandros Pennos
  • Harilaos Ginis
  • Lucia Hervella
  • Eloy A Villegas
  • Belen Cañizares
  • Jose Maria Marin
  • Ioannis Pallikaris
  • Pablo Artal
چکیده

PURPOSE To measure straylight in a cohort of patients with cataract using a novel optical instrument and to correlate optical straylight values with clinical grade of cataracts and psychophysical straylight values. METHODS Measurements were performed on 53 eyes of 44 patients with cataract admitted to the ophthalmology service of the university hospital in Murcia, Spain, and 9 young volunteers with no known ophthalmic pathology. Lens opacities were classified according to the Lens Opacities Classification System Ill (LOCS III) under slit-lamp examination. Intraocular straylight was additionally assessed psychophysically using the C-Quant straylight meter (Oculus Optikgeräte GmbH, Wetzlar, Germany). RESULTS Optical measurements of the logarithm of the straylight parameter ranged from 1.01 to 2.01 (mean: 1.43 ± 0.244) in patients with cataract and 0.80 to 1.08 (mean: 0.92 ± 0.104) in healthy young volunteers. Straylight differed by a statistically significant amount among different LOCS III groups (P < .05). Moreover, the optically measured straylight parameter was positively correlated to the psychophysically estimated value (r = 0.803, P < .05). CONCLUSIONS A new compact optical instrument suitable for clinical measurements of straylight in the human eye has been developed. Optically measured straylight values were highly correlated to those that were obtained psychophysically. Optical measurement of straylight can be used for the objective classification of cataract opacities based on their optical impact. [J Refract Surg. 2016;32(12):846-850.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in Intraocular Straylight and Visual Acuity with Age in Cataracts of Different Morphologies

PURPOSE To investigate the significance of difference in straylight of cataract eyes with different morphologies, as a function of age and visual acuity. METHODS A literature review to collect relevant papers on straylight, age, and visual acuity of three common cataract morphologies leads to including five eligible papers for the analysis. The effect of morphology was incorporated to categor...

متن کامل

Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. R...

متن کامل

Straylight effects with aging and lens extraction.

PURPOSE To assess possible gains and losses in straylight values among the population to consider straylight as added benefit of lens extraction. DESIGN In this cross-sectional design, data from a multicenter study on visual function in automobile drivers were analyzed. METHODS On both eyes of 2,422 subjects, visual acuity (logarithm of the minimum angle of resolution [logMAR] in steps of 0...

متن کامل

Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up.

PURPOSE To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction. SETTING Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS This study evaluated patients with bilateral age-related cataract who had cataract surgery with i...

متن کامل

Extensive drusen in type I membranoproliferative glomerulonephritis.

1. Van Den Berg TJ. On the relation between glare and straylight. Doc Ophthalmol. 1991;78(3-4):177-181. 2. Van Den Berg TJ, Van Rijn LJ, Michael R, et al. Straylight effects with aging and lens extraction. Am J Ophthalmol. 2007;144(3):358-363. 3. Cerviño A, Hosking SL, Montés-Micó R, Alió JL. Retinal straylight in patients with monofocal and multifocal intraocular lenses. J Cataract Refract Sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 32 12  شماره 

صفحات  -

تاریخ انتشار 2016