Validation of ENVISAT/SCIAMACHY columnar methane by solar FTIR spectrometry at the Ground-Truthing Station Zugspitze

نویسنده

  • R. Sussmann
چکیده

Methane total-vertical column retrievals from ground-based solar FTIR measurements at the Permanent Ground-Truthing Station Zugspitze (47.42 N, 10.98 E, 2964 m a.s.l.), Germany are used to validate column averaged methane retrieved from ENVISAT/SCIAMACHY spectra by WFM-DOAS (WFMD) version 0.4 and 0.41 for 153 days in 2003. Smoothing errors are estimated to be below 0.10% for FTIR and 0.14% for SCIAMACHY-WFMD retrievals and can be neglected for the assessment of observed bias and day-to-day-scatter. In order to minimize the altitude-difference effect, dry-air column averaged mixing ratios (XCH4) have been utilized. From the FTIRtime series of XCH4 an atmospheric day-to-day variability of 1% was found, and a sinusoidal annual cycle with a ≈1.6% amplitude. To obtain the WFMD bias, a polynomial fitted to the FTIR series was used as a reference. The result is WFMD v0.4/FTIR=1.008±0.019 and WFMD v0.41/FTIR=1.058±0.008. WFMD v0.41 was significantly improved by a time-dependent bias correction. It can still not capture the natural day-to-day variability, i.e., the standard deviation calculated from the daily-mean values is 2.4% using averages within a 2000-km radius, and 2.7% for a 1000km radius. These numbers are dominated by a residual timedependent bias in the order of 3%/month. The latter can be reduced, e.g., from 2.4% to 1.6% as shown by an empirical time-dependent bias correction. Standard deviations of the daily means, calculated from the individual measurements of each day, are excluding time-dependent biases, thus showing the potential precision of WFMD daily means, i.e., 0.3% for a 2000-km selection radius, and 0.6% for a 1000-km selection radius. Therefore, the annual cycle as well as possibly the day-to-day variability could be captured under the prerequisite of further advanced time-dependent bias corrections, or the use of other channels, where the icing issue is less prominent. Correspondence to: R. Sussmann ([email protected])

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of SCIAMACHY columnar methane by Zugspitze FTIR

Validation of ENVISAT/SCIAMACHY columnar methane by solar FTIR spectrometry at the Ground-Truthing Station Zugspitze R. Sussmann, W. Stremme, M. Buchwitz, and R. de Beek IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics (iup), University of Bremen FB1, Bremen, Germany Received: 27 January 2005 – Accepted: 23 March 2005 – Published: 13 April...

متن کامل

Initial validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals at the Ground-Truthing Station Zugspitze

Carbon monoxide vertical profile retrievals from ground-based solar FTIR measurements at the Permanent Ground-Truthing Station Zugspitze (47.42 N, 10.98 E, 2964 m a.s.l.), Germany are used to validate columnar CO retrieved from ENVISAT/SCIAMACHY spectra (WFMDOAS version 0.4). The WFM-DOAS retrievals of CO include an empirical column scaling factor of 0.5. Therefore, not absolute column levels a...

متن کامل

Validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals

Validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals at the Ground-Truthing Station Zugspitze R. Sussmann and M. Buchwitz IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics (iup), University of Bremen FB1, Bremen, Germany Received: 13 July 2004 – Accepted: 13 January 2005 – Published: 3 February 2005 Correspondence to: R. S...

متن کامل

Tropospheric NO2 from SCIAMACHY and Zugspitze FTIR

Stratospheric and tropospheric NO2 variability on the diurnal and annual scale: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch R. Sussmann, W. Stremme, J. P. Burrows, A. Richter, W. Seiler, and M. Rettinger IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics, University ...

متن کامل

Stratospheric and tropospheric NO2 variability on the diurnal and annual scale: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch

Columnar NO2 retrievals from solar FTIR measurements at the Zugspitze (47.42 N, 10.98 E, 2964 m a.s.l.), Germany were investigated synergistically with columnar NO2 retrieved from SCIAMACHY data by the University of Bremen scientific algorithm UB1.5 for the time span July 2002–October 2004. A new concept to match FTIR data to the time of satellite overpass makes use of the NO2 daytime increasin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005