Metric Calibration of a Focused Plenoptic Camera Based on a 3d Calibration Target

نویسندگان

  • N. Zeller
  • C. A. Noury
  • F. Quint
  • C. Teulière
  • U. Stilla
  • M. Dhome
چکیده

In this paper we present a new calibration approach for focused plenoptic cameras. We derive a new mathematical projection model of a focused plenoptic camera which considers lateral as well as depth distortion. Therefore, we derive a new depth distortion model directly from the theory of depth estimation in a focused plenoptic camera. In total the model consists of five intrinsic parameters, the parameters for radial and tangential distortion in the image plane and two new depth distortion parameters. In the proposed calibration we perform a complete bundle adjustment based on a 3D calibration target. The residual of our optimization approach is three dimensional, where the depth residual is defined by a scaled version of the inverse virtual depth difference and thus conforms well to the measured data. Our method is evaluated based on different camera setups and shows good accuracy. For a better characterization of our approach we evaluate the accuracy of virtual image points projected back to 3D space.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibration

The plenoptic camera can capture both angular and spatial information of the rays, enabling 3D reconstruction by single exposure. The geometry of the recovered scene structure is affected by the calibration of the plenoptic camera significantly. In this paper, we propose a novel unconstrained two-parallel-plane (TPP) model with 7 parameters to describe a 4D light field. By reconstructing scene ...

متن کامل

Calibration and Accuracy Analysis of a Focused Plenoptic Camera

In this article we introduce new methods for the calibration of depth images from focused plenoptic cameras and validate the results. We start with a brief description of the concept of a focused plenoptic camera and how from the recorded raw image a depth map can be estimated. For this camera, an analytical expression of the depth accuracy is derived for the first time. In the main part of the...

متن کامل

Stepwise calibration of focused plenoptic cameras

Monocular plenoptic cameras are slightly modified, off-the-shelf cameras that have novel capabilities as they allow for truly passive, high-resolution range sensing through a single camera lens. Commercial plenoptic cameras, however, are presently delivering range data in non-metric units, which is a barrier to novel applications e.g. in the realm of robotics. In this work we revisit the calibr...

متن کامل

On the Calibration of Focused Plenoptic Cameras

Plenoptic cameras provide a robust way to capture 3D information with a single shot. This is accomplished by encoding the direction of the incoming rays with a microlens array (MLA) in front of the camera sensor. In the focused plenoptic camera, a MLA acts like multiple small cameras that capture the virtual scene on the focus plane of a main lens from slightly different angles, which enables a...

متن کامل

Depth estimation and camera calibration of a focused plenoptic camera for visual odometry

This paper presents new and improved methods of depth estimation and camera calibration for visual odometry with a focused plenoptic camera. For depth estimation we adapt an algorithm previously used in structure-from-motion approaches to work with images of a focused plenoptic camera. In the raw image of a plenoptic camera, scene patches are recorded in several micro-images under slightly diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016