The design and control of a therapeutic exercise robot for lower limb rehabilitation: Physiotherabot

نویسندگان

  • Erhan Akdoğan
  • Mehmet Arif Adli
چکیده

0957-4158/$ see front matter 2011 Elsevier Ltd. A doi:10.1016/j.mechatronics.2011.01.005 ⇑ Corresponding author. Tel.: +90 212 383 28 88; f E-mail addresses: [email protected], eakdoga [email protected], [email protected] (M.A This study explains the design and control of three degrees of freedom therapeutic exercise robot (Physiotherabot) for the lower limbs of a patient who needs rehabilitation after a spinal cord injury (SCI), stroke, muscle disorder, or a surgical operation. In order to control this robot, a ‘‘Human–Machine Interface’’ with a rule-based control structure was developed. The robot manipulator (RM) can perform all active and passive exercises as well as learn specific exercise motions and perform them without the physiotherapist (PT) through the Human–Machine Interface. Furthermore, if a patient reacts against the robot manipulator during the exercise, the robot manipulator can change the position according to feedback data. Thus, the robot manipulator can serve as both therapeutic exercise equipment and as a physiotherapist in terms of motion capability. Experiments carried out on healthy subjects have demonstrated that the RM can perform the necessary exercise movements as well as imitate the manual exercises performed by the PT. 2011 Elsevier Ltd. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variable Impedance Control for Rehabilitation Robot using Interval Type-2 Fuzzy Logic

In this study, a novel variable impedance control for a lower-limb rehabilitation robotic system using voltage control strategy is presented. The majority of existing control approaches are based on control torque strategy, which require the knowledge of robot dynamics as well as dynamic of patients. This requires the controller to overcome complex problems such as uncertainties and nonlinearit...

متن کامل

Conceptual Design of a Gait Rehabilitation Robot

Gait rehabilitation using body weight support on a treadmill is a recommended rehabilitation technique for neurological injuries, such as spinal cord injury. In this paper, a new robotic orthosis is presented for treadmill training. In the presented design the criteria such as low inertia of robot components, backdrivability, high safety and degrees of freedom based on human walking are conside...

متن کامل

Upper limb rehabilitation robot for physical therapy: design, control, and testing

In recent years, the treatment process of patients and disabled people who need rehabilitation and physical medicine has become more effective with the use of new devices and developing technology. The rehabilitation robot is one of the most important developments in new technology. The right therapeutic exercises and the objectivity of the evaluation of the range of motion (ROM; generated torq...

متن کامل

the effect and persistence of Otago exercise program on balance, cardiovascular endurance and lower limb strength in elderly women with a history of falls

Introduction: Impaired balance is one of the consequences of aging that causes disruption and inability to function in these people and also causes the elderly to fall. All of this increases the importance of preventing the risk of falls for the elderly. Therefore, the aim of this study was to evaluate the effect and persistence of Otago exercise program on balance, cardiovascular endurance and...

متن کامل

Variable Impedance Control for Rehabilitation Robot using Interval Type-2 Fuzzy Logic

Received: June 18, 2015. Received in revised form: October 17, 2015. Accepted: October 26, 2015. In this study, a novel variable impedance control for a lower-limb rehabilitation robotic system using voltage control strategy is presented. The majority of existing control approaches are based on control torque strategy, which require the knowledge of robot dynamics as well as dynamic of patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011