Shape and refractive powers in corneal topography.

نویسندگان

  • S A Klein
  • R B Mandell
چکیده

PURPOSE To compare the relative advantages and disadvantages of four different representations of corneal power--identified as instantaneous, axial, position, and refractive--based on curvature, slope, coordinate position, and focal properties, respectively. METHOD The four types of corneal power were evaluated by examining their interrelationship for 12 hypothetical corneal shapes chosen to represent the general characteristics of regular, irregular, and surgically altered corneas. RESULTS There is only a limited association between refractive power and the other three powers, which are based on shape properties. For corneal shapes represented by ellipsoids of low eccentricity (e), refractive power increased as a function of the distance from the reference axis, whereas axial and instantaneous powers were either constant (for e = 0) or decreased, with instantaneous power having the largest decrease. Refractive power decreased for elliptical corneal shapes with eccentricities greater than the reciprocal of the index of refraction, although always decreasing less than the axial or instantaneous power. For various corneal shapes formed by segments of circles (or a polynomial) with large differences in instantaneous power, the refractive power was more closely associated with axial than instantaneous or position powers. CONCLUSIONS The Purkinje image measurements from videokeratograpy are most closely related to the slope-based axial power because it is slope that determines the direction of reflected rays forming the corneal image. Because of this direct connection, axial power is less sensitive to noise than is refractive, instantaneous, or position power. Present videokeratographs that report axial power provide an approximation of refractive power, but if an exact refractive power is needed it can be calculated easily. Instantaneous power provides the most sensitive measure of local curvature changes, such as those occurring in keratoconus or refractive surgery. There are unique practical applications for each of the four powers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اصلاح قوز قرنیه با استفاده از قطعات ‏حلقوی داخل قرنیه‌ای فرارا

  Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years).   Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...

متن کامل

Topographic Findings of the Porcine Cornea

The porcine eye is often used as an ex vivo animal model in ophthalmological research. It is well suited for investigations concerning refractive surgery; however, corneal topography data are scarce. This study investigated the corneal topography and pachymetry of the porcine eye to provide further reproducible data. We evaluated freshly enucleated porcine eyes (n = 16) by performing computeriz...

متن کامل

همبستگی آستیگماتیسم رفرکتیو، قرنیه‌ای و لنتیکولار در افراد داوطلب جراحی رفرکتیو

Background and purpose: Astigmatism is a common optical dysfunction, effective on various visual outcomes and one of the important criteria of refractive surgery. The aim of present study was to evaluate the correlation between refractive, corneal and residual astigmatism in refractive surgery candidates. Materials and methods: In this cross-sectional descriptive, analytical study, 200 patient...

متن کامل

Future challenges to aberration-free ablative procedures.

ne of the exciting new research areas in laser refractive surgery is the development of sophisticated devices to measure the wave-front of the optical system of the entire eye, the various implementations of which are described in this proceedings. The ability to objectively measure performance of the eye, as opposed to simple corneal shape, is critical to " customizing " ablation algorithms an...

متن کامل

Feasibility of intraoperative corneal topography monitoring during photorefractive keratectomy.

PURPOSE We propose a feasibility study of new corneal topography technology with the aim of monitoring intraoperative corneal topography during excimer laser photorefractive keratectomy. The PAR system measures corneal topography with single grid projection and triangulation but requires fluorescent fluid to be deposited on the corneal surface for shape extraction. We propose and demonstrate a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 1995