Temporal and Spatial Flap Variability in Laser In-Situ Keratomileusis by Optical Coherence Tomography

نویسندگان

  • Yousif Farhan Dawood
  • Usama Al Hassany
  • Ammar F. Issa
چکیده

PURPOSE To study changes in flap thickness made with two different microkeratome heads across different corneal locations using anterior segment optical coherence tomography (OCT). METHODS In this prospective, non-randomized, consecutive case series, subjects who had their laser in-situ keratomileusis (LASIK) flaps made using 90 μm (MSU90) or 130 μm (MSU130) disposable M2 microkeratome heads were examined using OCT. The measurements were performed at three locations (central and 2.5 mm to either side) at 1 day, 1 week, and 1 month postoperatively. RESULTS The central flap thickness was 123 ± 15, 130 ± 14, and 127 ± 13 μm, respectively, at 1 day, 1 week, and 1 month postoperatively in the MSU90 group (41 eyes) and 142 ± 20, 147 ± 19, and 143 ± 15 μm, respectively, in the MSU130 group (47 eyes). At 1 month, peripheral flap thickness was 161 ± 17 and 159 ± 13 μm, respectively, at 2.5 mm to the right and left of corneal center in the MSU90 group. The corresponding figures were 170 ± 14 and 167 ± 13 μm, respectively, in the MSU130 group. There was a statistically significant difference between the two groups at all locations (P < 0.001). No statistically significant change in flap thickness was detected in either group at any assessment time. There was a partial positive correlation (after controlling for preoperative manifest refractive spherical equivalent) between central flap thickness and preoperative ultrasound central pachymetry (r = 0.739, P = 0.036) in the MSU90 group but not in the MSU130 group. CONCLUSION Using OCT, changes in flap thickness were minimal in the first month after LASIK. Flap thickness correlated strongly with central corneal thickness if a 90 μm head was used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Optical Coherence Tomography on Corneal Surface Laser Ablation

This paper focuses on reviewing the roles of optical coherence tomography (OCT) on corneal surface laser ablation procedures. OCT is an optical imaging modality that uses low-coherence interferometry to provide noninvasive cross-sectional imaging of tissue microstructure in vivo. There are two types of OCTs, each with transverse and axial spatial resolutions of a few micrometers: the time-domai...

متن کامل

Topography-guided neutralization technique for the management of flap complication in laser in situ keratomileusis

A 29-year-old male was referred following a flap loss after the creation of a thin, irregular flap with a visual acuity of logMAR 0.1 with -2.0 DS-2.75 DC × 175°. Corneal topography and anterior segment optical coherence tomography revealed an irregular corneal curvature and epithelial profile. Phototherapeutic keratectomy (PTK) followed by Topography - Guided Custom Ablation Treatment (TCAT), ...

متن کامل

Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography.

PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of...

متن کامل

Factors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser

PURPOSE To evaluate factors responsible for the variability between intended and achieved corneal-flap thickness during femtosecond laser-assisted laser in situ keratomileusis (LASIK). METHODS A prospective, nonrandomized, case study was performed on 35 eyes of 18 consecutive patients who underwent LASIK surgery using the 60 kHz femtosecond laser microkeratome. Eyes were assigned to three dif...

متن کامل

Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK

PURPOSE To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). MATERIALS AND METHODS This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a des...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017