Closed Orbit Distortion and the Beam - Beam Interaction ∗
نویسنده
چکیده
We study the applicability of beam-beam deflection techniques as a tuning tool for the SLAC/LBL/LLNL B factory, PEP-II. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measurements, performed at points conveniently distant from the IP, provide distinct coordinateor frequency-space signatures that can be used to maintain the beams in collision and perform detailed optical diagnostics at the IP. A proposal to test this method experimentally at the TRISTAN ring is briefly discussed.
منابع مشابه
Beam-beam Diagnostics from Closed-orbit Distortion
We study the applicability of beam-beam deflection techniques as a tuning tool for asymmetric B factories, focusing on PEP-II as an example. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measureme...
متن کاملOrbit Distortion and the Beam - Beam Interaction ∗
We study the applicability of beam-beam deflection techniques as a tuning tool for the SLAC/LBL/LLNL B factory, PEP-II. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measurements, performed at poi...
متن کاملMagnet Alignment Method, Alignment Results and Closed Orbit Distortion for the SPring-8 Storage Ring
Abstract Third generation synchrotron radiation sources have high sensitivity against errors and large closed orbit distortion is generated resultantly. We found the alignment method to reduce the effective sensitivity and applied it to the SPring-8 storage ring. We succeeded to reduce the effective sensitivity substantially. Observed closed orbit distortions without correction were 1.4 mm for ...
متن کاملBeam-based Offset Calibration of the Pls Bpm
There are 108 beam position monitors in the PLS for the orbit measurement and closed orbit correction. As the BPM pickup electrodes are assembled directly on the 10m-long vacuum chamber, calibration of the electrical center of BPMs have been done with the external rf transmission-reflection method. Since the closed orbit distortion is still larger than 500 mm rms, we are developing the beam-bas...
متن کاملMechanical Induced Beam Motion in Srrc Storage Ring
It had been observed that the mechanical stability of some magnets had influences on the closed orbit in the storage ring. In this paper, a mechanical shaker in low vibration level was applied on the quadrupole magnet. The perturbation of the closed orbit was measured. The thermal induced distortion of magnet supporting structure was discussed. The motions of BPM and quadrupole magnet were meas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1992