SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress

نویسندگان

  • P. Simka
  • U. Straumann
چکیده

In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular the dielectric coordination of the contact systems becomes more and more challenging. The aim of the present work is to identify factors that may influence the dielectric coordination of contact systems with reduced coordination margin. The breakdown probability distribution of SF6 insulated multi-contact systems was investigated with the focus on two aspects. First of all, the breakdown probabilities under lightning impulse (LI) stress were measured. These indicated that it is not feasible to extrapolate the breakdown probability curves of single contacts to a combined full contact system. Secondly, the findings on the same contact system stressed with very fast transient voltages (VFT) showed a considerable reduction in breakdown voltage and suggested a significant increase in the main contact breakdown probability, compared to the LI tests. The results and interpretation within this work indentified the polarity and voltage shape dependent breakdown initiation of different contacts as causes for circuit breaker contact system

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes

In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...

متن کامل

Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA

In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...

متن کامل

Effect of Lightning Impulse Voltage on the Performance of 1-phase Gas Insulated Busduct in the Presence of Metallic Particle Contamination with Sf6/n2 Gas Mixtures

SF6 is the main mode of insulation in a GIS. However, in recent years, the future use of SF6 has been debated throughout the world in spite of it having all the desirable properties of a good insulating and arc quenching medium. Sulfur hexafluoride (SF6) has been used as a gaseous dielectric (insulator) in high voltage equipment since the 1950s. It is now known that SF6 is a potent greenhouse w...

متن کامل

Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm

Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...

متن کامل

Transient Minimization Within Static Var Compensated Distribution Systems

VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012