Achieving λ/10 Resolution CW STED Nanoscopy with a Ti:Sapphire Oscillator

نویسندگان

  • Yujia Liu
  • Yichen Ding
  • Eric Alonas
  • Wenli Zhao
  • Philip J. Santangelo
  • Dayong Jin
  • James A. Piper
  • Junlin Teng
  • Qiushi Ren
  • Peng Xi
چکیده

In this report, a Ti:Sapphire oscillator was utilized to realize synchronization-free stimulated emission depletion (STED) microscopy. With pump power of 4.6 W and sample irradiance of 310 mW, we achieved super-resolution as high as 71 nm. With synchronization-free STED, we imaged 200 nm nanospheres as well as all three cytoskeletal elements (microtubules, intermediate filaments, and actin filaments), clearly demonstrating the resolving power of synchronization-free STED over conventional diffraction limited imaging. It also allowed us to discover that, Dylight 650, exhibits improved performance over ATTO647N, a fluorophore frequently used in STED. Furthermore, we applied synchronization-free STED to image fluorescently-labeled intracellular viral RNA granules, which otherwise cannot be differentiated by confocal microscopy. Thanks to the widely available Ti:Sapphire oscillators in multiphoton imaging system, this work suggests easier access to setup super-resolution microscope via the synchronization-free STED.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STED Nanoscopy with Time-Gated Detection: Theoretical and Experimental Aspects

In a stimulated emission depletion (STED) microscope the region in which fluorescence markers can emit spontaneously shrinks with continued STED beam action after a singular excitation event. This fact has been recently used to substantially improve the effective spatial resolution in STED nanoscopy using time-gated detection, pulsed excitation and continuous wave (CW) STED beams. We present a ...

متن کامل

Sub-Abbe resolution: from STED microscopy to STED lithography

Commonly, in stimulated emission depletion (STED) fluorescence nanoscopy, light of a wavelength located at the red tail of the emission spectrum of the dye is used to shrink the effective fluorophore excitation volume and thus to obtain images with sub diffraction resolution. Here, we demonstrate that continuous wave (CW) STED nanoscopy is feasible using STED wavelengths located at the emission...

متن کامل

2PE-STED Microscopy with a Single Ti: Sapphire Laser for Reduced Illumination

We reported a new effective approach to carry out two-photon excitation stimulated emission depletion (2PE-STED) microscopy using a single Ti:sapphire laser system. With an acoustic-optic Bragg cell, the modulated-CW 2PE STED microscope had the benefits of both CW and pulse approaches: lower input power, simple optical scheme and no complicated synchronization. Additionally, it also took advant...

متن کامل

STED nanoscopy with fluorescent quantum dots

The widely popular class of quantum-dot molecular labels could so far not be utilized as standard fluorescent probes in STED (stimulated emission depletion) nanoscopy. This is because broad quantum-dot excitation spectra extend deeply into the spectral bands used for STED, thus compromising the transient fluorescence silencing required for attaining super-resolution. Here we report the discover...

متن کامل

gSTED Microscopy with an OPSL: Cutting Edge Super-Resolution Breaking the diffraction limit with a CW OPSL

In order to probe cell biology at the molecular level and correlate single molecule activity with macroscopic cellular behavior in real-time, biologists need farfield microscopy techniques with the highest possible spatial as well as temporal resolution. Driven by this need, the use of lasers in confocal microscopy has taken fluorescence microscopy to the diffraction limit, which was long consi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012