Co/Ni ratios at taenite/kamacite interfaces and relative cooling rates in iron meteorites

نویسندگان

  • John T. Wasson
  • Peter Hoppe
چکیده

We report a pilot study of a new technique to use the distribution of Co between kamacite and taenite to infer relative cooling rates of iron meteorites; data of Widge and Goldstein (1977) showed that the distribution is temperature dependent. A plot of the logarithm of the double ratio [(Co/Ni)kamacite/(Co/Ni)taenite] (abbreviated Rac) against inverse temperature yields a linear equation showing that the ratio ranges from 2.5 at 1080 K to 30 at 710 K. Thus, a measurement of Rac in the kamacite and taenite near the interface offers information about relative cooling rates; the higher Rac, the lower the cooling rate. A major advantage of this technique is that it is mainly affected by the final (low-temperature) cooling rate, just before the sample cooled to the blocking temperature where diffusion became insignificant. To test this method we used the NanoSIMS ion probe to measure Rac in two IVA and two IIIAB irons; members of each pair differ by large factors in elemental composition and in published metallographic cooling rates (Yang and Goldstein, 2006; Yang et al., 2008). Despite differing by a factor of 25 in estimated metallographic cooling rate, the two IVA irons showed similar Rac values of 22. If experimental uncertainties are considered this implies that, at low temperatures, their cooling rates differ by less than a factor of 5 with 95% confidence, i.e., significantly less than the range in metallographic cooling rates. In contrast, the IIIAB irons have different ratios; Rac in Haig is 29 whereas that in Cumpas, with a reported cooling rate 4.5 times lower, is 22, the opposite of that expected from the published cooling rates. A reevaluation of the Yang–Goldstein IIIAB data set shows that Haig has anomalous metallographic properties. We suggest that both the high Rac in Haig and the systematically low taenite central Ni contents are the result of impact-produced fractures in the taenite that allowed equilibration with kamacite down to lower temperatures but shut down Ni transport to the interiors of taenite lamellae. Our observations of similar Rac values in IVA irons differing by a factor of 25 in metallographic cooling rates implies that there was, in fact, only a comparatively small difference in low-temperature cooling rates in IVA irons; because we studied only two IVA irons, this conclusion will remain tentative until further studies can be completed. 2012 Elsevier Ltd. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining cooling rates of iron and stony-iron meteorites from measurements of Ni and Co at kamacite–taenite interfaces

Analyses and modeling of Ni zoning in taenite in differentiated meteorites provide metallographic cooling rates at 500 C that are inconsistent with conventional formation models. Group IVA iron meteorites have very diverse cooling rates of 100–6600 C/Myr indicating that they cooled inside a large metallic body with little or no silicate mantle (Yang et al., 2007). Wasson and Hoppe (2012) have q...

متن کامل

Cooling Rate Variations of Group Wa Iron Meteorites

Cooling rates of eight group IVA iron meteorites were determined using a modification of the Wood method where cooling rate curves are calculated as a function of central taenite Ni content and taenite half-width. The ma jor modification of the Wood method was to include the effect of? on the Ni solubility limits and Ni diffusion co efficients in the kamacite phase for each meteorite studied. T...

متن کامل

Composition and Thermal History of the Ivb Iron Meteorites

Introduction: Among the magmatic iron meteorites, group IVB irons have some unusual characteristics, such as high bulk Ni (15-18 wt%), high refractory elements (e.g., Ir), low volatile elements (e.g., Ga, Ge) [1, 2], fast cooling rates and a small parent body [3, 4]. IVB irons do not have a Widmanstatten pattern as in lower Ni IIIAB or IVA irons. Instead, IVB irons have a plessite structure wit...

متن کامل

Rapid methods of determining cooling rates of iron and stony iron meteorites.

Two rapid and simple methods have been developed for determining the approximate cooling rates of iron and stony-iron meteorites in which kamacite formed by diffusion-controlled growth along planar fronts. The first method requires only measurements of the mean kamacite bandwidth and the bulk nickel content. The second method requires the determination of the nickel composition near the taenite...

متن کامل

An Improved Model to Determine the Cooling Rates of Mesosiderites and Iron

Introduction: Data on the Ni concentration and distribution in kamacite (α) and taenite (γ) of meteoritic metal can be used to determine the cooling rates of meteorites. Several metallographic cooling rate methods have been used to determine the cooling rates of meteorites and have been recently reviewed [1]. The reliability of these models depends on the accuracy of the phase diagram and diffu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012