Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
نویسندگان
چکیده
BACKGROUND AND PURPOSE Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS We evaluated the sensitivity and specificity of preoperative ultrasound for detecting pseudotumors in 82 patients with MoM hip replacement (82 hips). Ultrasound examinations were performed by 1 of 3 musculoskeletal radiologists, and pseudotumors seen by ultrasound were retrospectively classified as fluid-filled, mixed-type, or solid. Findings at revision surgery were retrieved from surgical notes and graded according to the same system as used for ultrasound findings. RESULTS Ultrasound had a sensitivity of 83% (95% CI: 63-93) and a specificity of 92% (CI: 82-96) for detecting trochanteric region pseudotumors, and a sensitivity of 79% (CI: 62-89) and a specificity of 94% (CI: 83-98) for detecting iliopsoas-region pseudotumors. Type misclassification of pseudotumors found at revision occurred in 8 of 23 hips in the trochanteric region and in 19 of 33 hips in the iliopsoas region. INTERPRETATION Despite the discrepancy in type classification between ultrasound and revision findings, the presence of pseudotumors was predicted well with ultrasound in our cohort of failed MoM hip replacements.
منابع مشابه
Comparison of extracapsular pseudotumors seen in magnetic resonance imaging and in revision surgery of 167 failed metal-on-metal hip replacements
BACKGROUND AND PURPOSE Magnetic resonance imaging (MRI) is important for detecting extracapsular pseudotumors, but there is little information on the accuracy of MRI and appropriate intervals for repeated imaging. We evaluated the sensitivity and specificity of MRI for detecting pseudotumors in 155 patients (167 hips) with metal-on-metal (MoM) hip arthroplasties that failed due to adverse react...
متن کاملA comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty
BACKGROUND AND PURPOSE Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy....
متن کاملSensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement.
Blood metal ions have been widely used to investigate metal-on-metal hip replacements, but their ability to discriminate between well-functioning and failed hips is not known. The Medicines and Healthcare products Regulatory Agency (MHRA) has suggested a cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate the sensitivity and specificity of ...
متن کاملRunning head: PSEUDOTUMORS IN ASSOCIATION WITH HIP PROSTHESES 1 PSEUDOTUMORS IN ASSOCIATION WITH HIP PROSTHESES: A LITERTURE REVIEW WITH CASE STUDIES November 13, 2013 PSEUDOTUMORS IN ASSOCIATION WITH HIP PROSTHESES
With the exhibit of pseudotumor discoveries around hip replacements, the search for the cause of such abnormal masses has become a topic of great interest. Possible areas of causation include metal-on-metal hip replacements compared to metal-on-polyethylene hip replacements, patient hypersensitivity to prosthesis debris, or even prosthesis surgical position has been investigated. Although more ...
متن کاملHigh blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements
Background and purpose - There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 86 شماره
صفحات -
تاریخ انتشار 2015