Bus Protection Considerations for Various Bus Types

نویسندگان

  • Caitlin Martin
  • Steven Chase
  • Thanh-Xuan Nguyen
  • Dereje Jada Hawaz
  • Jeff Pope
  • Casper Labuschagne
چکیده

Choosing a bus protection scheme requires several key considerations. The complexity of bus protection varies considerably depending on such factors as the bus layout, allowed bus switching scenarios, availability of suitable current transformers (CTs), and maintenance issues. Buses with statically assigned zone currents are well suited for the use of high-impedance bus relaying (if suitable CTs are available) and do not require disconnect status inputs. For substations with terminals capable of switching between different buses, it is necessary to dynamically assign input currents to the bus zones of protection based on the disconnect auxiliary contact status. To avoid misoperations resulting from disconnect auxiliary contact failures, such substation configurations can require the use of a second trip criterion, such as a check zone. Low-impedance numerical relays are especially well suited for protecting more complex bus configurations with dynamic zone selection because they enable zone reconfiguration without any need for corresponding changes to physical CT wiring. While bus differential relaying provides protection for all bus arrangements, fast bus tripping and directional elements can provide adequate protection for some arrangements. Surge arresters and CTs (depending on their placement, saturation, and ratio) generally influence bus protection scheme selection and performance. This paper examines several common bus configurations, presents appropriate protection schemes for each configuration, and analyzes the protection scheme complexity, advantages, and disadvantages.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental impact assessment of bus rapid transit (BRT) in the Metropolitan City of Tehran

Bus rapid transit is an innovative, high capacity, lower cost public transit solution in metropolitan cities. Idea is to dedicate lanes for quick and efficient transport of passengers to their destinations. In the present investigation the environmental impact assessment of bus rapid transit  in Tehran metropolitan city is brought out. For this purpose bus rapid transit Lane No. 10 is investiga...

متن کامل

Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative Study

IEC 61850-9-2 is an international substation automation standard that proposes a Process Bus communication network between process level equipment and bay level Intelligent Electronic Devices (IEDs) used for power systems protection and control. This paper considers the drive towards the use of IEC 61850-9-2 Process Bus in substations. The impact of the IEC 61850-9-2 standard on the operating p...

متن کامل

Providing Optimal Pricing Model for Urban Bus Services (Tehran Case Study)

Utilities and services can be divided into two types of public and private goods in terms of the nature of pricing. Urban bus services are pure private goods that have positive externality. The Mohering effect is one of the most important externality of bus services, which in fact justifies the philosophy and nature of subsidies by the municipality and the government. In this study, monetary ca...

متن کامل

Reconfiguration and optimal placement of distributed generations in distribution networks in the presence of remote voltage controlled bus using exchange market algorithm

Abstract: Since distribution networks have a large share of the losses in power systems, reducing losses in these networks is one of the key issues in reducing the costs of global networks, including issues Which has always been considered. In this thesis, the reconfiguration of the distribution network in the presence of distributed generation sources (DGs) with respect to two types of bus, P ...

متن کامل

A Comprehensive Study on IEC61850 Process Bus Architecture and Spit Bus Based Differential Protection

IEC61850 communication standard for digital substation automation creates a new way to think about conventional protection scheme and configuration of substation. The presence of communication link in process bus makes a revolutionary change for future digital substation. This paper discusses briefly about process bus architecture and presents a new approach of thinking in busbar structure to m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015