Increased serum bromide may result from the ingestion of various drugs and from environmental exposures. Chloride methods that are less susceptible to bromide interference have a clinical disadvantage in that they are less likely to arouse suspicion in cases of bromide toxicity. When there is a clinical suspicion of bromide toxicity, differences among various analyzers in the amount of interference caused by bromide may be exploited to confirm this suspicion and to estimate the concentration of bromide in serum.
منابع مشابه
Colorimetric measurement of serum bromide with a bromate-rosaniline method.
A procedure is presented for measuring bromide in serum filtrates, after protein has been precipitated with a HCI-tungstate reagent. The bromide in the filtrate isoxidized to bromate with hypochlorite. The resulting bromate reacts with added bromide to release bromine. Bromine reacts with rosaniline to form bromorosaniline, which is measured colorimetrically. The method is specific, sensitive, ...
متن کاملInterference of bromide in the Zak ferric chloride-sulfuric acid cholesterol method, and means of eliminating this interference.
HE AUTHORS’ LABORATORY has employed the modified Zlatkis method (1) of Zak and associates (2) for the routine determination of serum cholesterol fractions for over a year with generally satisfactory results. However, ester fractions greater than 80 per cent of the total cholesterol values were occasionally obtained. Recently, an analysis of the serum “total cholesterol” from a patient with acut...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملDirect determination of valproic acid in biological fluids by capillary electrophoresis with contactless conductivity detection.
Capacitively coupled contactless conductivity detection (C(4)D) is a new technique providing high sensitivity in capillary electrophoresis (CE) especially for small ions that can otherwise only be determined with indirect methods. In this work, direct determination and validation of valproic acid (VPA) in biological fluids was achieved using CE with C(4)D. VPA is of pharmacological interest bec...
متن کاملIs color "categorical perception" really perceptual?
Roberson and Davidoff (2000) found that color categorical perception (CP; better cross-category than within-category discrimination) was eliminated by verbal, but not by visual, interference presented during the interstimulus interval (ISI) of a discrimination task. On the basis of this finding, Roberson and Davidoff concluded that CP was mediated by verbal labels, and not by perceptual mechani...