EUVL dosimetry at NIST

نویسندگان

  • C. Tarrio
  • S. Grantham
  • M. Cangemi
  • R. E. Vest
  • T. B. Lucatorto
  • Noreen Harned
چکیده

As part of its role in providing radiometric standards in support of industry, the National Institute of Standards and Technology has been active in advancing extreme ultraviolet dosimetry on various fronts. Recently, we undertook a major effort in accurately measuring the sensitivity of three extreme ultraviolet photoresists. It has been common practice to use photoresists as a transfer “standards” to determine the intensity and uniformity of the radiation transmitted by extreme ultraviolet steppers. In response to preliminary results from Lawrence Berkeley National Laboratory that showed that two “standard” photoresists were almost twice as sensitive as had been previously believed, NIST carried out similar measurements and confirmed the Berkeley results. However, we have found that the assumed sensitivities are more a question of system calibration than of absolute resist dose sensitivity. We will describe the facility we used to make these measurements. Photoresists make less than perfect radiometers. They are very non-linear, sensitive to atmosphere, and difficult to calibrate. All of these characteristics led to the disparate results in assumed sensitivity values. We have developed an alternate wafer-plane dosimeter based on image plates. The dosimeter is linear over several orders of magnitude, comparatively insensitive to atmosphere, and can be re-calibrated as necessary. Moreover it can pass through a stepper as any other wafer. We will describe this dosimeter in detail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A transferability study of the EPR-tooth-dosimetry technique.

The transferability of a measurement protocol from one laboratory to another is an important feature of any mature, standardised protocol. The electron paramagnetic resonance (EPR)-tooth dosimetry technique that was developed in Scientific Center for Radiation Medicine, AMS, Ukraine (SCRM) for routine dosimetry of Chernobyl liquidators has demonstrated consistent results in several inter-labora...

متن کامل

Recommendations of the American Association of Physicists in Medicine on 103Pd interstitial source calibration and dosimetry: implications for dose specification and prescription.

The National Institute of Standards and Technology (NIST) introduced a national standard for air kerma strength of the ThreaSeed Model 200 103Pd source (the only 103Pd seed available until 1999) in early 1999. Correct implementation of the NIST-99 standard requires the use of dose rate constants normalized to this same standard. Prior to the availability of this standard, the vendor's calibrati...

متن کامل

Recent Dosimetry Activities at the NIST

The following is intended as a general overview of activities by the Radiation Interaction and Dosimetry Group, Ionizing Radiation Division, National Institute of Standards and Technology (NIST), USA, for the meeting of Section I (X and γ rays, electrons) of the Consultative Committee on Ionizing Radiation (CCRI), May 13-15, 2009, Paris. The material was taken from information gathered for NIST...

متن کامل

Radon monitor calibration using NIST radon emanation standards: steady flow method.

The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....

متن کامل

Extreme Ultraviolet Lithography: Towards the Next Generation of Integrated CircuitsTHE VIEWPOINT - Optical lattice solitons: Guiding and routing light at will

Lithography is the most challenging technology in the semiconductor industry. The most promising next generation lithography technology is extreme ultraviolet lithography (EUVL). EUVL was proposed long ago, in 1988, but its implementation has been postponed several times. Presently, most “showstoppers” are gone, but there are still several challenges that need to be addressed. The semiconductor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009