Modified hemagglutination-inhibition test for rubella employing human group O erythrocytes.

نویسندگان

  • N J Schmidt
  • J Dennis
چکیده

A hemagglutination-inhibition (HI) test for rubella is described which utilizes human group O, rather than 1-day-old chick, erythrocytes. The test was found to be as sensitive and reproducible for detection of rubella antibody as HI tests employing chick erythrocytes. Advantages to the use of human erythrocytes are (i) they are more available, (ii) it is unnecessary to absorb natural agglutinins from human test sera, and (iii) heparin-MnCl(2)-treated sera do not agglutinate human erythrocytes, as is sometimes the case with chick erythrocytes. Factors influencing the reliability of the test are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the hemolysis-in-gel test for the screening of rubella immunity and the demonstration of recent infection.

The hemolysis-in-gel method for detection of antibodies to rubella virus gave results which correlated well with results of hemagglutination inhibition and neutralization tests. With a diffusion time of 24 or 48 h, a linear correlation was obtained between the logarithm of antibody concentration and the diameter of the hemolytic zone. Fourfold, and even twofold, differences in serum antibody co...

متن کامل

Trypsin-Modified Human Erythrocytes

A method of treating human erythrocytes with trypsin has been modified and found to be an efficient and practical indicator system for the rubella hemagglutination-inhibition test. Both the trypsin-treated human cells and the widely used, newborn chicken erythrocytes were used in comparative testing of 464 selected diagnostic rubella serums. Results with each cell system were essentially the sa...

متن کامل

Use of a new buffer system with formalinized sheep erythrocytes in the rubella hemagglutination-inhibition test.

The increased sensitivity and improved agglutination and settling patterns of formalinized sheep erythrocytes in a new buffer, HEPES (N-2-hydroxyethylpiperazine N'-2'-ethanesulfonic acid), make this system more suitable for use in the rubella hemagglutination-inhibition test.

متن کامل

Detection of rubella haemagglutination-inhibition (HAI) and virus-specific IgM antibody using trypsin-treated human group O erythrocytes in the HAI test.

The modification of the standard rubella haemagglutination-inhibition (HAI) test using trypsin-treated human group O erythrocytes instead of chick erythrocytes was evaluated. In a comparative study we found that, of 816 samples tested by both methods, the titres of 807 (98.9%) sera were in close agreement within an acceptable twofold difference. Trypsin-treated human group O erythrocytes usuall...

متن کامل

Analysis of the diluents used for rubella virus hemagglutination and hemagglutination-inhibition tests.

A new diluent (ADGP) for the rubella virus hemagglutination (HA) and hemagglutination-inhibition (HI) tests is described. It was found that the HA and HI titers and the erythrocyte agglutination pattern were improved in ADGP compared to previously described diluents. The influence of the components of ADGP and of various test conditions on optimal HA and HI results were examined.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1972