Scanning electrochemical microscopy (SECM) in the constant-height mode was used to image individual gold nanowires (AuNWs, 2–3 mm long and 140 nm diameter). High-resolution negative and positive feedback current images of individual AuNWs immobilized on glass and gold-coated glass slides, respectively, were recorded with a Wollaston-based platinum disk ultramicroelectrode (UME) of radius 300 nm at 0.3 V probe potential using ferrocenemethanol as the mediator. The negative and positive feedback current responses were dependent on the effective recycling of the mediator on the unbiased AuNWs. Furthermore, the AuNWs were covalently linked to horseradish peroxidase (HRP) and immobilized on a thin film gold substrate. Positive feedback and localized HRP activity over individual AuNWs were imaged subsequently by switching the probe potential from 0.3 V to 0 V after the addition of H2O2. In this measurement, ferrocenemethanol behaved both as the mediator (feedback response at 0.3 V probe potential) and the electron donor for HRP (in the presence of H2O2 for activity imaging at 0 V).
منابع مشابه
Electrochemical fabrication of Cu/Pd multilayer nanowires in polycarbonate template
In this work,copper/palladium (Cu/Pd) multilayer nanowires were successfully prepared by electrodeposition method using polycarbonate template. The fabrication of Pd/Cu multilayer nanowires was controlled by analyzing the current–time transient during electrodeposition using potentiostat. The morphological properties of the nanowires were studied by scanning electron microscopy (SEM) and resu...
متن کاملElectrochemical imaging of hydrogen peroxide generation at individual gold nanoparticles.
Localised hydrogen peroxide generation at individual catalytic gold nanoparticles within ensemble electrodes is mapped for the first time using combined scanning electrochemical-scanning ion conductance microscopy (SECM-SICM).
متن کاملImaging of DNA hybridization on microscopic polypyrrole patterns using scanning electrochemical microscopy (SECM): the HRP bio-catalyzed oxidation of 4-chloro-1-naphthol.
We illustrate in this paper the successful combination of the direct and feedback mode of scanning electrochemical microscopy (SECM) for the writing of oligonucleotide patterns on thin gold films alongside the imaging of DNA hybridization. The patterning process was achieved using the direct mode of SECM, where the electrical field established between the SECM tip and the gold interface was use...
متن کاملSoft microelectrode linear array for scanning electrochemical microscopy.
A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime. Similar to previous reports, the soft microelectrode array was fabricated by ablating microchannels on a polyethylene terephthalate (PET) film and filling them with carbon ink. Improvemen...
متن کاملScanning electrochemical microscopy. 24. Enzyme ultramicroelectrodes for the measurement of hydrogen peroxide at surfaces.
Hydrogen peroxide sensing microelectrodes for scanning electrochemical microscopy (SECM) have been developed and used to measure hydrogen peroxide in the diffusion layer during electrochemical reduction of oxygen on gold and carbon electrodes. These microelectrode biosensors were also used to detect immobilized glucose oxidase through the production of hydrogen peroxide during enzymatic oxidati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016