[Topographic localization of an intraocular foreign body by B-scan echography].

نویسندگان

  • Ivan Stefanović
  • Bojana Dacić
  • Sasa Novak
  • Dragan Veselinović
  • Predrag Jovanović
  • Boban Dzunić
  • Branislav Tomasević
چکیده

BACKGROUND/AIM In cases of blurred optic media the ultrasound diagnostics offers useful data about eventual presence of intraocular foreign body as well as about its precise localization in the eye. The aim of this study was to retrospectively analyze echographic findings in patients with the diagnosis of intraocular foreign body with a special interest in localizations of a intraocular foreign body in the eye and the presence of an eventual infection - endophthalmitis. The aim of this study was also to confirm the localization of intraocular foreign body by echography and to test the precision of this method. METHODS We performed analysis of all cases that had been referred to the ultrasound diagnostices, in which the presence of intraocular foreign body had been confirmed in the period of one year. All examinations were done with B-scan and were confirmed during the surgery - vitrectomy. RESULTS In the one-year period we were contacted by 27 patients with intraocular foreign body. In one injured eye the intraocular foreign body was in the lens (3.70%), in 10 injured eyes (37.03%) intraocular foreign body was in the vitreal body. In 15 patients (55.5%) intraocular foreign body was fixed in the retina. In one patient (3.70%) there was a perforating injury, intraocular foreign body was found in the retrobulbar part of the orbit. In 7 injured eyes (25.9%), with the presence of intraocular foreign body, we found signs of endophthalmitis (organized blurring in vitreal space, thickened choroid). Other accompanying echographic findings were: blood in vitreal space, haemophthalmus in 12 cases (44.4%), retinal detachment in 5 cases (18.5%) and subretinal hemorrhagies in 4 cases (14.8%). CONCLUSION Ultrasound diagnostics can very precisely show the localization of intraocular foreign body in the eye that is very important in the choice of approach and timing of surgical treatment. Also the echographic diagnostics may find an accompanying endophthalmitis in the posterior segment of the eye, that is very important for an urgent therapeutic approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis and surgical management of an intraocular foreign body secondary to ballistic wound in a Rhesus macaque (Macaca mulatta)

Background: Intraocular foreign bodies (IOFBs) such as air gun pellet is a rare finding in wild animals like Rhesus macaque (Macaca mulatta). The purpose of the present scientific report is to describe the surgical retrieval of IOFB secondary to ballistic wound in a wild Rhesus macaque. Case description: A juvenile female wild Rhesus macaque was brought with the history of swollen and inflamed ...

متن کامل

Role of B-scan ultrasonography in the localization of intraocular foreign bodies in the anterior segment: a report of three cases

BACKGROUND The accurate localization of intraocular foreign bodies (IOFBs) is very important for the management of ocular trauma patients. B-scan ultrasonography is usually used to detect IOFBs in the posterior segment. Here, we report three cases with IOFBs in the anterior segment near the posterior lens capsule, which were accurately localized by B-scan ultrasonography under dynamic transvers...

متن کامل

Iraq-Iran War-related Intraocular Foreign Body Injuries in Veterans

According to military documents, the incidence of ocular injuries significantly increases. Intraocular foreign body (IOFB) is one of the ocular damages that seriously threats vision. Many ocular injuries occurred in a war between Iran and Iraq from 1980 to 1988. The aim of the present study was to review ocular damages made by IOFB in this war, different methods of treatment and their prognosis.

متن کامل

CLINICAL SCIENCE Interobserver and intraobserver variability of measurements of uveal melanomas using standardised echography

Aim: To report on the intraindividual and interindividual variability of tumour size (height and base diameter) measurements using standardised echography in a masked prospective study. Methods: 20 consecutive eyes of 20 patients were examined on four different visits by three experienced examiners using standardised echography. As common in standardised echography, tumour height was evaluated ...

متن کامل

Interobserver and intraobserver variability of measurements of uveal melanomas using standardised echography.

AIMS To report on the intraindividual and interindividual variability of tumour size (height and base diameter) measurements using standardised echography in a masked prospective study. METHODS 20 consecutive eyes of 20 patients were examined on four different visits by three experienced examiners using standardised echography. As common in standardised echography, tumour height was evaluated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vojnosanitetski pregled

دوره 67 3  شماره 

صفحات  -

تاریخ انتشار 2010