Improved Resource Utilization With Similar Efficacy During Early Adoption of Cryoballoon Pulmonary Vein Isolation as Compared to Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.

نویسندگان

  • Donald Siddoway
  • Mati Friehling
  • Andrew Voigt
  • Samir Saba
  • Sandeep Jain
چکیده

BACKGROUND Cryoballoon pulmonary vein isolation (PVI) is an alternative to radiofrequency (RF) PVI for the treatment of paroxysmal atrial fibrillation (AF). Treatment effect, complication rates, and hospital length of stay are not well established with early use of cryoballoon PVI as compared to more experienced performance of RF PVI. PURPOSE We reviewed the early experience of cryoballoon PVIs for paroxysmal AF performed by 3 operators at our institution compared to their most recent RF PVIs. All repeat procedures were excluded. Patients were assessed for recurrence of AF at 6 months after the procedure, including a 3-month blanking period. Complications, procedure time, and hospital length of stay were recorded. METHODS Consecutive patients presenting to the ER with ECG-documented AF at an urban teaching hospital were treated according to a guideline-based care protocol, including a patient toolkit at ER discharge, and systematic referral to a rapid access AF clinic. Consenting patients received questionnaires on AF knowledge, patient satisfaction, and the AFEQT questionnaire at first visit and three-month follow-up. RESULTS Final analysis included 50 cryoballoon PVIs and 50 RF PVIs. There was no significant difference in baseline characteristics or percentage of patients wearing a home monitor (80% for cryoballoon vs 80% for RF). Symptomatic improvement was experienced by 96% of cryoballoon PVI as compared to 86% of RF PVI patients (p=0.08). Freedom from AF at 6 months was similar between the two groups (70% for cryoballoon and 70% for RF, p=1). Complications were seen in 6% of cryoballoon procedures as compared to 10% of RF procedures (p=0.46). Hospital length of stay was significantly shorter in the cryoballoon group (1.6 vs 3.4 nights, p=0.003). CONCLUSION At the time of its adoption, cryoballoon PVI is associated with shorter procedure times and hospital length of stay as compared to RF PVI in experienced operators while maintaining similar efficacy outcomes and complication rates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary vein stenosis after second-generation cryoballoon ablation for atrial fibrillation

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF), especially in paroxysmal 1 AF patients. In addition to a radiofrequency ablation catheter, a cryoballoon has been proven as an effective technology in PVI for AF. Recently several randomized trials have shown that cryoballoon ablation was noninferior to radiofrequency ablation with respect to ef...

متن کامل

Comparing Safety and Efficacy of Irrigated Radiofrequency Catheter Ablation Versus Combined Cryoballoon and Catheter Ablation for Persistent Atrial Fibrillation.

Background: Catheter and cryoballoon ablation are established treatments for atrial fibrillation. Frequently, substrate modification of the left atrium is performed in patients with persistent AF or evidence of left atrial adverse remodeling. We compared one year outcomes of AF ablation with substrate modification utilizing radiofrequency catheter ablation (RFA) compared to a combination of cry...

متن کامل

Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation

Catheter ablation (CA) is an accepted treatment option for symptomatic atrial fibrillation (AF). Historically, CA has been performed with a point-by-point technique, using standard focal radiofrequency catheters and 3-dimensional (3D) navigation systems, with a procedural end point of electric pulmonary vein isolation (PVI). However, this CA approach requires advanced training and operator skil...

متن کامل

Cryoballoon dysfunction indicated by abrupt temperature drop during atrial fibrillation ablation.

Pulmonary vein (PV) isolation remains the cornerstone of atrial fibrillation (AF) ablation. Cryoballoon ablation is shown to be non-inferior to radiofrequency ablation in terms of efficacy and safety among paroxysmal AF patients. In this case, we report an intraprocedural adverse event encountered during cryoballoon ablation. A 46-year-old male patient with symptomatic, paroxysmal AF underwent ...

متن کامل

Cryoballoon Ablation for Atrial Fibrillation: a Comprehensive Review and Practice Guide

The cryoballoon was invented to achieve circumferential pulmonary vein isolation more efficiently to compliment the shortcomings of point-by-point ablation by radiofrequency ablation (RFA). Its efficacy and safety were shown to be comparable to those of RFA, and the clinical outcomes have improved with the second-generation cryoballoon. The basic biophysics, implemental techniques, procedural r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of atrial fibrillation

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2015