Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

نویسندگان

  • Colm McAlinden
  • Qinmei Wang
  • Konrad Pesudovs
  • Xin Yang
  • Fangjun Bao
  • Ayong Yu
  • Shishi Lin
  • Yifan Feng
  • Jinhai Huang
  • Chen-Wei Pan
چکیده

PURPOSE To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. METHODS Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis. RESULTS AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x2 = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (β = -1.491, P<0.001) and Lenstar LS 900 (β = -1.507, P<0.001). CONCLUSION The IOLMaster and Lenstar LS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Axial length measurement acquisition rates of two optical biometers in cataractous eyes

PURPOSE To compare the ability of two optical biometers to acquire the axial length (AL) measurement in cataractous eyes. METHODS This prospective, comparative, single-center study comprised 105 eyes (63 patients). AL was acquired by the composite mean value of 20 measurements (composite-20 IM) and five measurements (composite-5 IM) (IOLMaster(®) 500 version 7.1 software), and the standard me...

متن کامل

Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500

PURPOSE To compare the measurements and failure rates obtained with a new swept source optical coherence tomography (OCT)-based biometry to IOLMaster 500. SETTING Eye Clinic, Baskent University Faculty of Medicine, Ankara, Turkey. DESIGN Observational cross-sectional study and evaluation of a new diagnostic technology. METHODS 188 eyes of 101 subjects were included in the study. Measureme...

متن کامل

Evaluation of Optical Low Coherence Reflectometry Parameters in Patients with Exfoliation Syndrome

Purpose. To evaluate optical low coherence reflectometry (OLCR) parameters in patients with exfoliation syndrome (EXS) undergoing cataract surgery. Methods. Forty-seven eyes of 47 patients with EXS (Group 1), and 55 eyes of 55 healthy subjects (Group 2) were included in the study. Anterior chamber depth (ACD), lens thickness (LT), axial length (AL), central corneal thickness (CCT), horizontal c...

متن کامل

مقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت

Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...

متن کامل

The impact of cataract severity on measurement acquisition with the IOLMaster.

PURPOSE The Zeiss IOLMaster optical biometry system provides superior prediction of refractive outcome of cataract surgery compared to applanation ultrasound. However, measurement is not always possible in the presence of dense cataract. The purpose of this study was to elucidate the rate of measurement acquisition failure due to cataract and how this varies with morphology and severity. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015