Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.
نویسندگان
چکیده
With image-guided tomotherapy, highly targeted total marrow irradiation (TMI) has become a feasible alternative to conventional total body irradiation. The uncertainties in patient localization and intrafraction motion of the whole body during hour-long TMI treatment may pose a risk to the safety and accuracy of targeted radiation treatment. The feasibility of near-infrared markers and optical tracking system (OTS) is accessed along with a megavoltage scanning system of tomotherapy. Three near-infrared markers placed on the face of a rando phantom are used to evaluate the capability of OTS in measuring changes in the markers' positions as the rando is moved in the translational direction. The OTS is also employed to determine breathing motion related changes in the position of 16 markers placed on the chest surface of human volunteers. The maximum uncertainty in locating marker position with the OTS is 1.5 mm. In the case of normal and deep breathing motion, the maximum marker position change is observed in anterior-posterior direction with the respective values of 4 and 12 mm. The OTS is able to measure surface changes due to breathing motion. The OTS may be optimized to monitor whole body motion during TMI to increase the accuracy of treatment delivery and reduce the radiation dose to the lungs.
منابع مشابه
Prostate stereotactic body radiotherapy with simultaneous integrated boost: which is the best planning method?
BACKGROUND The delivery of a simultaneous integrated boost to the intra-prostatic tumour nodule may improve local control. The ability to deliver such treatments with hypofractionated SBRT was attempted using RapidArc (Varian Medical systems, Palo Alto, CA) and Multiplan (Accuray inc, Sunnyvale, CA). MATERIALS AND METHODS 15 patients with dominant prostate nodules had RapidArc and Multiplan p...
متن کاملFeasibility study for linac-based intensity modulated total marrow irradiation.
Total body irradiation (TBI) is used as a preconditioning regimen prior to bone marrow transplant for treatment of hematologic malignancies. During TBI, large volumes of normal tissue are irradiated, and this can lead to toxicities, most significantly in the lungs. Intensity modulated total marrow irradiation (IMTMI) may be able to reduce these toxicities by directly targeting the bone marrow w...
متن کاملReview of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry
Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...
متن کاملTargeted total marrow irradiation using three-dimensional image-guided tomographic intensity-modulated radiation therapy: an alternative to standard total body irradiation.
Total body irradiation (TBI) is an important part of bone marrow transplantation conditioning regimens. In TBI, dose escalation is difficult, because of associated normal organ toxicities. A method to deliver a more targeted dose of TBI preferentially to sites of greatest tumor burden is needed to reduce the dose to normal organs, reduce toxicities, and permit dose escalation. The purpose of th...
متن کاملTHE INTERACTION OF RADIATION AND INTERCALATING AGENTS IN NORMAL BONE MARROW CELLS AS EVALUATED BY SPLEEN COLONY ASSAY TECHNIQUE: THE EFFECTS OF BLEOMYCIN SULFATE AND ACT INOMYCIND.
The relationship between the way in which normal hemopoietic stem cells respond to irradiation alone or in the presence of bleomycin sulfate (BLM-S) and actinomycin 0 (ACT-D) was investigated. Single doses of BLM-S at 0.3 mg/kg and ACT-O at 0.10 mg/kg body weight were injected intravenously 1-6 hours prior to whole body irradiation and treatment was repeated twice more with time intervals....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2011