Efficacy of full-fat milk and diluted lemon juice in reducing infra-cardiac activity of 99mTc sestamibi during myocardial perfusion imaging

نویسندگان

  • Khushica Purbhoo
  • Mboyo Di Tamba
  • Willy Vangu
چکیده

BACKGROUND When using (99m)Tc sestamibi for myocardial perfusion imaging, increased splanchnic activity creates a problem in the visual and quantitative interpretation of the inferior and infero-septal walls of the left ventricle. We sought to determine whether the administration of diluted lemon juice or full-fat milk would be effective in reducing interfering infra-cardiac activity and therefore result in an improvement in image quality. We compared the administration of full-fat milk and diluted lemon juice to a control group that had no intervention. METHODS The study was carried out prospectively. All patients referred to our institution for myocardial perfusion imaging from November 2009 to May 2012 were invited to be enrolled in the study. A total of 630 patients were randomised into three groups. Group 0 (G0), 246 patients, were given diluted lemon juice, group 1 (G1), 313 patients, were given full-fat milk, and group 2 (G2), 71 patients, had no intervention (control group). A routine two-day protocol was used and the patients were given the same intervention on both days. Raw data of both the stress and rest images were visually assessed for the presence of infra-cardiac activity, and quantitative grading of the relative intensity of myocardial activity to infra-cardiac activity was determined. The physicians were blinded to the intervention received and the data were reviewed simultaneously. RESULTS The overall incidence of interfering infra-cardiac activity at stress was 84.1, 84.5 and 96.6% in G0, G1 and G2, respectively (p = 0.005). At rest it was 91.7, 90.1 and 100% in G0, G1 and G2, respectively (p = 0.0063). The visual and quantitative results favoured both milk and lemon juice in reducing the amount of interfering infra-cardiac activity versus no intervention. CONCLUSION The administration of milk or lemon juice resulted in a significant decrease in the intensity of infra-cardiac activity compared to the control group. This reduction in intensity was even more significant in the milk group for patients assessed during rest myocardial perfusion imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of pomegranate juice, lemon juice and secanjabin in reducing infra-cardiac activity of 99mTc-MIBI during myocardial perfusion imaging in comparison with fatty food

Introduction: Eating fatty food is a common technique for decreasing extra cardiac activity, but sometimes patients refuse to eat fatty foods due to various reasons during myocardial perfusion imaging. The aim of this study is to introduce an alternative method for patients who are not able to use fatty foods to accelerate the transit of radiotracer from the liver. <stron...

متن کامل

Erythromycin as an alternative to reduce interfering extra-cardiac activity in myocardial perfusion imaging

OBJECTIVES We sought to determine whether taking oral erythromycin prior to SPECT myocardial perfusion imaging with Tc99m-sestamibi would reduce the amount of interfering extra-cardiac activity and improve the image quality. METHODS A total of 96 patients who were routinely referred for myocardial perfusion imaging were randomly assigned to one of two groups. Patients in group A received 500 ...

متن کامل

The Effect of Milk, Water and Lemon Juice on Various Subdiaphragmatic Activity-Related Artifacts in Myocardial Perfusion Imaging

BACKGROUND Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI). OBJECTIVES We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using (99m)Tc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasi...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

Translation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction

Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2015