A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model.

نویسندگان

  • Bryan Terry
  • Gordy Gunst
  • Richard Melchior
  • David Wolfe
  • Nancy Feocco
  • Susan Graham
  • Bruce Searles
  • Edward Darling
چکیده

In the United States, standardization of neonatal extracorporeal membrane oxygenation (ECMO) circuit was achieved during the 1980s. Since that time, the consoles and components of the ECMO circuit have remained fundamentally unchanged (bladder, rollerpump, silicone membrane oxygenator). Extracorporeal technology, however, has witnessed many significant advancements in components during the past two decades. These new technologies have characteristics that may improve outcomes when applied in the ECMO arena. Understanding how these technologies perform in long-term applications is necessary. Therefore, the purpose of this project is to evaluate the performance of a miniature ECMO circuit consisting of current generation technologies in an animal model. An ECMO circuit (prime volume 145 mL) was designed that included a hollow fiber oxygenator and a remote mounted centrifugal pump. All circuit tubing and components were surface coated. Three sheep (approx 13 kg) were placed on ECMO using standard neck cannulation techniques and maintained according to clinical protocols. Technical implementation, oxygenator function, and hematological parameters were accessed. Duration of ECMO was 20, 48, and 58 hours. There was no evidence of oxygenator failure, as measured by pressure drop and oxygen transfer, in any of the procedures. No plasma leak was observed in any oxygenators. Platelet count trended downward after 24 hours. Visual inspection after ECMO showed very little evidence of gross thrombosis. This ECMO circuit design departs dramatically from the typical North American systems. The use of this console and components facilitated a 70% reduction in priming volume over a traditional ECMO circuit. Further investigations should be conducted to determine if circuit miniaturization can reduce the morbidity associated with blood product consumption and the bloods contact with the artificial surfaces of the ECMO circuitry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-way valve malfunction in an extracorporeal membrane oxygenation priming circuit.

Developing technologies have changed both the components and the management style when extracorporeal membrane oxygenation (ECMO) is used to support critically ill cardiac and respiratory patients. The Cardiohelp system is a small, portable extracorporeal system just recently available within the United States. Manufacturing standards and quality processes have made mechanical failure and malfu...

متن کامل

Can physicochemical properties of antimicrobials be used to predict their pharmacokinetics during extracorporeal membrane oxygenation? Illustrative data from ovine models.

INTRODUCTION Ex vivo experiments in extracorporeal membrane oxygenation (ECMO) circuits have identified octanol-water partition coefficient (logP, a marker of lipophilicity) and protein binding (PB) as key drug factors affecting pharmacokinetics (PK) during ECMO. Using ovine models, in this study we investigated whether these drug properties can be used to predict PK alterations of antimicrobia...

متن کامل

Pharmacokinetics of midazolam in neonates undergoing extracorporeal membrane oxygenation.

BACKGROUND Although the pharmacokinetics of midazolam in critically ill children has been described, there are no such reports in extracorporeal membrane oxygenation. METHODS The pharmacokinetics of midazolam and 1-hydroxy midazolam after continuous infusion (50-250 microg. kg(-1). h(-1)) were determined in 20 neonates undergoing extracorporeal membrane oxygenation. Patients were randomized i...

متن کامل

Protection of platelets during long-term extracorporeal membrane oxygenation in sheep with a single dose of a disintegrin.

BACKGROUND Both short- and long-term extracorporeal membrane oxygenation (ECMO) causes platelet loss and dysfunction. Bitistatin is a reversible inhibitor of the platelet glycoprotein IIb/IIIa receptor. This study tests the hypothesis that inhibition of platelets by bitistatin during initial contact with the perfusion circuit preserves platelet number and function during long-term ECMO in sheep...

متن کامل

Membrane Oxygenation: A Case Report

Amphotericin B treatment during extracorporeal membrane oxygenation is at times necessary for the treatment of secondary fungemia or, less commonly, to treat a primary fungal infection. The impact of the extracorporeal circuit on the pharmacokinetics of amphotericin B have not been described in vivo. This case report describes the pharmacokinetics of amphotericin B in a patient receiving extrac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2005