Assessment of intracranial blood flow velocities using a computer controlled vasoactive stimulus: a comparison between phase contrast magnetic resonance angiography and transcranial Doppler ultrasonography.

نویسندگان

  • Jackie Leung
  • Amir Behpour
  • Neil Sokol
  • Arun Mohanta
  • Andrea Kassner
چکیده

PURPOSE To compare measurements of blood flow velocity (BFV) and BFV changes in the middle cerebral arteries (MCA) acquired from phase contrast magnetic resonance angiography (PCMRA) and transcranial Doppler ultrasound (TCD) during controlled manipulation of end-tidal partial pressure of carbon dioxide (PetCO2 ). MATERIALS AND METHODS In vivo TCD and PCMRA velocity data from the M1 segment in the MCA of nine healthy adult volunteers were acquired during precise targeting of PetCO2 induced by a computer-controlled gas delivery system. Doppler spectra and phase contrast data were processed into time-averaged peak-velocity (TAPV) values for comparison. Changes in velocity between baseline and hypercapnia were analyzed in terms of velocity-based cerebrovascular reactivity (CVR). RESULTS Good correlation between the pairs of velocity measurements acquired from the two modalities were found (ρ = 0.81), but Bland-Altman analysis indicates a significant bias error. There was relatively weak agreement between the pairs of computed CVR values (ρ = -0.26). CONCLUSION Under precise PetCO2 control, PCMRA proves to be more consistent than TCD. Despite issues with variability, TCD is qualitatively comparable to PCMRA measures of velocity in the MCA. However, PCMRA velocity results are better suited for analyses that require quantitative values, such as CVR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Assessment of the Cerebral Venous System velocities using Virtual Navigator Technology and Magnetic Resonance Imaging

The interest about the cerebral venous system has recently grown attention mainly due to the definition of the Chronic Cerebro-spinal Venous Insufficiency (CCSVI) syndrome. Examining a patient for CCSVI criteria, intracranial veins and sinuses are insonated from a new transcranial (TC) ultrasound (US) window, i.e. at the level of the condyloid bone of the mandible. The present work describes th...

متن کامل

Advanced Imaging Modalities in the Detection of Cerebral Vasospasm

The pathophysiology of cerebral vasospasm following aneurysmal subarachnoid hemorrhage (SAH) is complex and is not entirely understood. Mechanistic insights have been gained through advances in the capabilities of diagnostic imaging. Core techniques have focused on the assessment of vessel caliber, tissue metabolism, and/or regional perfusion parameters. Advances in imaging have provided clinic...

متن کامل

The Findings of Transcranial Doppler Ultrasonography in Patients with Ischemic Stroke

Background: Stroke is a multifactorial disorder, the most common cause being arterial occlusion. Transcranial Doppler Ultrasonography (TCD) is a common non-invasive method available for assessment the arterial blood flow of the brain. Objective: Assessment the hemodynamic parameters of cerebral arteries, using TCD device in patients suffering ischemic stroke. Materials and Methods: This descr...

متن کامل

Diastolic function imaging: a comparison of real-time phase contrast magnetic resonance (CMR) imaging with segmented phase contrast CMR and Doppler echocardiography

Background CMR measurement of mitral inflow velocities for the assessment of diastolic function is often infeasible in patients with dyspnea patients who may benefit the most due to their inability to breath-hold. Although real-time phase contrast (RT-PC) imaging may overcome this limitation, it has not been systematically evaluated. The objective of this study was to assess the accuracy of RT-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2013