Automated cold vapour flow-injection analysis of mercury at high concentrations

نویسندگان

  • W. T. Corns
  • L. C. Ebdon
  • S. J. Hill
  • P. B. Stockwell
چکیده

Continuous-flow cold vapour- atomic fluorescence spectrometry is shown to be an extremely sensitive technique for the determination of mercury with detection limits typically below 0.01 mug l(-1). Linear calibration ranges were found to be at least four orders of magnitude (i.e. up to 0.1 mg l(-1)). Samples with concentrations exceeding the linear range are susceptible to self-absorption, and may, in severe cases, cause carry-over problems between samples. The flow-injection approach has been utilized to extend the upper limit of the linear calibration range allowing determinations up to 10 mg l(-1) of mercury. A range of certified reference materials and zinc battery anodes have been successfully analysed with a minimal number of sample dilutions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated continuous monitoring of inorganic and total mercury in wastewater and other waters by flow-injection analysis and cold-vapour atomic absorption spectrometry

An automated continuous monitoring system for the determination of inorganic and total mercury by flow-injection analysis followed by cold-vapour atomic absorption spectrometry is described. The method uses a typical flow-injection manifold where digestion and reduction of the injected sample takes place. Mercury is removed by aeration from the flowing stream in a specially designed air-liquid ...

متن کامل

Determination of total mercury in biological tissues by flow injection cold vapour generation atomic absorption spectrometry following tetramethylammonium hydroxide digestion.

A simple, rapid and reliable method was developed for the determination of total mercury in biological samples. Samples were solubilized using tetramethylammonium hydroxide (TMAH). The organically bound mercury was cleaved and converted to inorganic mercury by on-line addition of KMnO4. The decomposed mercury together with inorganic mercury originally present in samples was determined by flow i...

متن کامل

Inorganic, organic, and total mercury in blood and urine: cold vapor analysis with automated flow injection sample delivery.

A cold vapor atomic absorption technique for blood or urine mercury analysis that uses persulfate oxidation to prepare samples for total mercury analysis and acid permanganate oxidation to prepare samples for inorganic mercury analysis is described. The linearity of the procedures ranged from 0.5 to 25 micrograms/L. Precision ranged from 20% at 1 microgram/L to 7% at 20 micrograms/L. Documentat...

متن کامل

Adaptation of a cold vapour mercury analyser to flow injection analysis

Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 mul it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 mug. l(-1) (120 pg) of mercury. The authors also report on a simple digestion procedure which replaces the time- and reagent-consuming EPA procedure, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1991