Verification of Abbott 25-OH-vitamin D assay on the architect system

نویسندگان

  • Katrina Hutchinson
  • Martin Healy
  • Vivion Crowley
  • Michael Louw
  • Yury Rochev
چکیده

OBJECTIVES Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. METHODS Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. RESULTS For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients' samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24-111 nmol/L). CONCLUSION In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

INTRODUCTION Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). MATERIALS AND METHODS One hundred venous blood samples were randomly selected ...

متن کامل

Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities

BACKGROUND The purpose of this study was to find out the cause of discrepancy between various automated immunoassays for 25-hydroxy-vitamin D (25-[OH]D). METHODS National Institute of Standards & Technology Standard Reference Material (SRM) 972a is SRM for 25-(OH)D and consists of 4 vials of frozen serum with different concentrations of 25-(OH)D. Each concentration was measured 6 times in 3 d...

متن کامل

What is the definition of \"vitamin D deficiency\" and who is considered \"vitamin D deficient\"? Urgent need for a national consensus

since early works on isolation and characterization of vitamin D by Elmer Verner McCollum and Edward Mellanby in 1900s, this molecule still seems mysterious (1-2). After several decades since discovery of the miraculous effect of cod liver oil in treatment of nutritional rickets, escalating number of reports provide a huge body of evidence for various effects of vitamin D ...

متن کامل

Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples.

Introduction: In serum, 25-hydroxy-vitamin D (25(OH)D) can be found in two forms, namely 25(OH)D2 and 25(OH)D3. We recently published a mathematical method to estimate the 25(OH)D2 recovery without spiking the samples. Since then, new “total” vitamin D immunoassays have appeared on the market (Roche “Total” vitamin D, Siemens Centaur vitamin D “total”, “total” vitamin D on DiaSorin Liaison XL, ...

متن کامل

Outi Itkonen 2,3* Influence of Vitamin D 2 Percentage on Accuracy of 4 Commercial Total 25- Hydroxyvitamin D Assays

25-Hydroxyvitamin D (25-OHD) is the most appropriate marker for monitoring vitamin D storage status. The 2 major forms of 25OH-D [25-OH-D2 (D2) and 25OH-D3 (D3)], differ slightly in molecular structures but have essentially the same physiological activity. Therefore, both D2 and D3 should be measured to assess vitamin D status. At our laboratory, 42% of patient samples submitted for vitamin D t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017