Design of an integrated hardware interface for AOSLO image capture and cone-targeted stimulus delivery
نویسندگان
چکیده
We demonstrate an integrated FPGA solution to project highly stabilized, aberration-corrected stimuli directly onto the retina by means of real-time retinal image motion signals in combination with high speed modulation of a scanning laser. By reducing the latency between target location prediction and stimulus delivery, the stimulus location accuracy, in a subject with good fixation, is improved to 0.15 arcminutes from 0.26 arcminutes in our earlier solution. We also demonstrate the new FPGA solution is capable of delivering stabilized large stimulus pattern (up to 256 x 256 pixels) to the retina.
منابع مشابه
Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking.
We have developed a new, unified implementation of the adaptive optics scanning laser ophthalmoscope (AOSLO) incorporating a wide-field line-scanning ophthalmoscope (LSO) and a closed-loop optical retinal tracker. AOSLO raster scans are deflected by the integrated tracking mirrors so that direct AOSLO stabilization is automatic during tracking. The wide-field imager and large-spherical-mirror o...
متن کاملAdaptive optics scanning laser ophthalmoscope-based microperimetry.
PURPOSE To develop and test the application of an adaptive optics scanning laser ophthalmoscope (AOSLO) with eye tracking for high-resolution microperimetric testing. METHODS An AOSLO was used to conduct simultaneous high-resolution retinal imaging and visual function testing in six normal subjects. Visual sensitivity was measured at test locations between the fovea and 5.0° eccentricity via ...
متن کاملThe reliability of parafoveal cone density measurements
BACKGROUND Adaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements. METHODS For the interobserver reliability study, 30 subjects with no vision-li...
متن کاملIntrinsic signals from human cone photoreceptors.
PURPOSE To develop noninvasive means to relate structure to function in human eyes, the authors investigated intrinsic retinal signals at high resolution using an adaptive optics scanning laser ophthalmoscope (AOSLO). METHODS The AOSLO was used in dual-wavelength mode to stimulate the retina with 658 nm visible light and simultaneously to image the retina with 840 nm infrared light. Modulatio...
متن کاملDysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis
PURPOSE Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. METHODS A patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2010