چکیده

Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite). Ten screws of each type were attached applying a 30.07+/-0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72+/-8.98 N), followed by surface-treated titanium screws (97.78+/-4.68 N) and titanium screws (37.03+/-5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review

Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and Methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external...

متن کامل

A clinical study of the efficacy of gold-tite square abutment screws in cement-retained implant restorations.

PURPOSE The purpose of this study was to record the effectiveness of Gold-Tite square abutment screws, tightened to 35 Ncm with a torque indicator, in maintaining a clinically stable implant/abutment connection. MATERIALS AND METHODS The study consisted of 73 patients who were treated with 110 Osseotite implants. All patients were restored with either pre-machined titanium or customized UCLA ...

متن کامل

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

The Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses.

PURPOSE To examine the effect of different torque application techniques (torqued, retorqued once, and retorqued twice) on the removal torque of implant-supported fixed complete dental prostheses. MATERIALS AND METHODS Four Nobel Biocare implants (4.3 × 13 + 3; 13-mm thread height + 3-mm collar height) were stabilized temporarily inside four holes made in an acrylic mandibular master model. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2008