Saphenous vein conduits harvested by endoscopic technique exhibit structural and functional damage.
نویسندگان
چکیده
BACKGROUND Injury to the saphenous vein endothelium during harvest impacts patency after coronary artery bypass graft surgery. Many centers are adopting endoscopic saphenous vein harvest (ESVH) instead of using the traditional open saphenous vein harvest (OSVH) technique. Our objective was to compare the effects of ESVH and OSVH on the structural and functional viability of saphenous vein endothelium using multiphoton imaging, immunofluorescence, and biochemical techniques. METHODS Ten patients scheduled for coronary artery bypass graft surgery were prospectively identified. Each underwent ESVH for one portion and OSVH for another portion of the saphenous vein. A 1-cm segment from each portion was immediately transported to the laboratory for processing. The vessel segments were labeled with fluorescent markers to quantify cell viability (esterase activity), calcium mobilization, and generation of nitric oxide. Samples were also labeled with immunofluorescent antibodies to visualize caveolin, endothelial nitric oxide synthase, von Willebrand factor, and cadherin, and extracted to identify these proteins using Western blot techniques. All labeling, imaging, and image analysis was done in a blinded fashion. RESULTS Esterase activity was significantly higher in the OSVH group (p < 0.0001). Similarly, calcium mobilization and nitric oxide production were significantly greater in the OSVH group (p = 0.0209, p < 0.0001, respectively). Immunofluoresence and Western blot techniques demonstrated an abnormal alteration in distribution of caveolin and endothelial nitric oxide synthase in the ESVH group. CONCLUSIONS Our study indicates that ESVH has a detrimental effect on the saphenous vein endothelium, which may lead to decreased graft patency and worse patient outcomes.
منابع مشابه
Endoscopic vein harvest of the lesser saphenous vein in the supine position: a unique approach to an old problem.
OBJECTIVES To obtain a suitable conduit from the lesser (short) saphenous system for use in coronary artery bypass surgery. We wanted to perform this while the patient was in the supine position as to not disrupt the standard operation, and at the same time, utilizing the endoscopic vein harvest technique with its obvious abilities to decrease vein harvest morbidity. We also theorized that thro...
متن کاملIncreased Contractile Function of Human Saphenous Vein Grafts Harvested by “No-Touch” Technique
Saphenous vein grafts are the most common conduits used for coronary artery bypass grafting (CABG); however, no more than 60% of vein grafts remain open after 10 years and graft failure is associated with poor clinical outcome. The "no-touch" harvesting technique-where a sheet of perivascular tissue is retained around the vein-improves graft patency to over 80% after 16 years of follow-up, but ...
متن کاملEvaluation of endoscopic vein extraction on structural and functional viability of saphenous vein endothelium
OBJECTIVES Endothelial injury during harvest influences graft patency post CABG. We have previously shown that endoscopic harvest causes structural and functional damage to the saphenous vein (SV) endothelium. However, causes of such injury may depend on the extraction technique. In order to assess this supposition, we evaluated the effect of VirtuoSaph endoscopic SV harvesting technique (VsEVH...
متن کاملThe Short Saphenous Vein: A Viable Alternative Conduit for Coronary Artery Bypass Grafts Harvested Using a Novel Technical Approach
A multitude of vascular conduits are available to the Cardiac Surgeon performing Coronary Artery Bypass Graft operations. The Internal Mammary Artery, Radial Artery (RA), and the Long Saphenous Vein (LSV) have proven to be excellent conduits, especially in the current era of statin usage. However, previous stripping or varicosities of the LSV and calcification of the RA, coupled with the need f...
متن کاملSimultaneous endoscopic radial artery and great saphenous vein harvesting for redo coronary artery bypass grafting. A report of two cases.
AIM An ageing population and increase in patient co-morbidities are forcing cardiac surgeons to meticulously consider the benefits and risks of respective conduits and their harvesting techniques. CASE REPORTS Two cases of simultaneous endoscopic radial artery and great saphenous vein harvesting, for redo coronary artery bypass grafting, are presented. A shortage of venous conduits after prev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of thoracic surgery
دوره 87 1 شماره
صفحات -
تاریخ انتشار 2009