A Diagnostic Accuracy Study of Xpert®MTB/RIF in HIV-Positive Patients with High Clinical Suspicion of Pulmonary Tuberculosis in Lima, Peru
نویسندگان
چکیده
BACKGROUND Diagnosis of pulmonary tuberculosis (TB) among human immunodeficiency virus (HIV) patients remains complex and demands easy to perform and accurate tests. Xpert®MTB/RIF (MTB/RIF) is a molecular TB diagnostic test which is rapid and convenient; the test requires minimal human resources and reports results within two hours. The majority of performance studies of MTB/RIF have been performed in high HIV burden settings, thus TB diagnostic studies among HIV patients in low HIV prevalence settings such as Peru are still needed. METHODOLOGY/PRINCIPAL FINDINGS From April 2010 to May 2011, HIV-positive patients with high clinical suspicion of TB were enrolled from two tertiary hospitals in Lima, Peru. Detection of TB by MTB/RIF was compared to a composite reference standard Löwenstein-Jensen (LJ) and liquid culture. Detection of rifampicin resistance was compared to the LJ proportion method. We included 131 patients, the median CD4 cell count was 154.5 cells/mm(3) and 45 (34.4%) had TB. For TB detection among HIV patients, sensitivity of MTB/RIF was 97.8% (95% CI 88.4-99.6) (44/45); specificity was 97.7% (95% CI 91.9-99.4) (84/86); the positive predictive value was 95.7% (95% CI 85.5-98.8) (44/46); and the negative predictive value, 98.8% (95% CI 93.6-99.8) (84/85). MTB/RIF detected 13/14 smear-negative TB cases, outperforming smear microscopy [97.8% (44/45) vs. 68.9% (31/45); p = 0.0002]. For rifampicin resistance detection, sensitivity of MTB/RIF was 100% (95% CI 61.0-100.0) (6/6); specificity was 91.0% (95% CI 76.4-96.9) (30/33); the positive predictive value was 66.7% (95% CI 35.4-87.9) (6/9); and the negative predictive value was 100% (95% CI 88.7 -100.0) (30/30). CONCLUSIONS/SIGNIFICANCE In HIV patients in our population with a high clinical suspicion of TB, MTB/RIF performed well for TB diagnosis and outperformed smear microscopy.
منابع مشابه
The utility of Xpert MTB/RIF performed on bronchial washings obtained in patients with suspected pulmonary tuberculosis in a high prevalence setting
BACKGROUND Xpert MTB/RIF has been shown to have a superior sensitivity to microscopy for acid fast bacilli (AFB) in sputum and has been recommended as a standard first line investigation for pulmonary tuberculosis (PTB). Bronchoscopy is a valuable tool in diagnosing PTB in sputum negative patients. There is limited data on the utility of Xpert MTB/RIF performed on bronchial lavage specimens. Ou...
متن کاملDiagnostic Accuracy of the Small Membrane Filtration Method for Diagnosis of Pulmonary Tuberculosis in a High-HIV-Prevalence Setting.
Sputum acid-fast bacilli (AFB) smear microscopy has suboptimal sensitivity but remains the most commonly used laboratory test to diagnose pulmonary tuberculosis (TB). We prospectively evaluated the small membrane filtration (SMF) method that concentrates AFB in a smaller area to facilitate detection to improve the diagnostic performance of microscopy. We enrolled adults with suspicion of pulmon...
متن کاملDiagnostic accuracy of Xpert MTB/RIF for tuberculosis detection in different regions with different endemic burden: A systematic review and meta-analysis
PURPOSE To estimate the diagnostic accuracy of Xpert MTB/RIF, a systematic review and meta-analysis were carried out. METHODS Up to June 20, 2015, multiple databases were screened for relevant studies. RESULTS Accordingly, 106 studies included 52,410 samples were selected. Diagnostic accuracy of Xpert MTB/RIF for TB detection was validated against either culture or a composite reference sta...
متن کاملXpert MTB/RIF for diagnosis of tuberculous cervical lymphadenitis in HIV-infected patients.
OBJECTIVES/HYPOTHESIS The World Health Organization endorsed the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis (TB), but there is limited information about the utility of this assay for the diagnosis of TB lymphadenitis. Therefore, the objective of this study was to assess the diagnostic accuracy of Xpert MTB/RIF assay in HIV-infected patients with palpable cervical lymph node...
متن کاملRapid and Accurate Detection of Mycobacterium tuberculosis in Sputum Samples by Cepheid Xpert MTB/RIF Assay—A Clinical Validation Study
BACKGROUND A crucial impediment to global tuberculosis control is the lack of an accurate, rapid diagnostic test for detection of patients with active TB. A new, rapid diagnostic method, (Cepheid) Xpert MTB/RIF Assay, is an automated sample preparation and real-time PCR instrument, which was shown to have good potential as an alternative to current reference standard sputum microscopy and cultu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2012