Accuracy of the Justy II Apex locator in determining working length in simulated horizontal and vertical fractures.
نویسندگان
چکیده
AIM To study the effectiveness of an electronic apex locator (EAL; Justy II; Yoshida Dentcraft, Tokyo, Japan) in locating simulated horizontal and vertical fractures in single roots. METHODOLOGY An EAL was used to measure the distance within the canal of horizontal (n = 31) and vertical (n = 31) fractures, created with a disk in single-rooted teeth. Accuracy of the EAL was evaluated by comparing the measurements with those made using a size 10 file. Data were analysed with the non-parametric Passing and Bablok method. RESULTS For simulated horizontal fractures, the EAL measured exactly the same length as a size 10 file, without constant or proportional errors. In vertical simulated fractures, the EAL measured (on average) with a constant error of 7.5 mm shorter than the size 10 file; the difference had a wide confidence interval (-72.3 to 2.6 mm). CONCLUSIONS In this laboratory study, the Justy II EAL was able to determine accurately the position of simulated horizontal fractures, but was unreliable when measuring simulated vertical fractures.
منابع مشابه
Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملEffects of simulated lateral canals on the accuracy of measurements by an electronic apex locator.
BACKGROUND Accurate determination of the apical terminus plays a significant role in the success of root canal therapy, but accuracy may be affected by the presence of accessory canals. OBJECTIVE To evaluate the accuracy of a ratio-based electronic apex locator for roots with simulated lateral canals. METHODS Forty-two single-rooted human teeth were randomly divided into 2 groups. For each ...
متن کاملارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)
Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...
متن کاملAccuracy of the Raypex-4 and Propex apex locators in detecting horizontal and vertical root fractures: an in vitro study.
Unforeseen root fractures during endodontic therapy are often difficult to diagnose and treat. Apex locators have been shown to be accurate in measuring the working lengths of root canals, and it was postulated whether they could also be used to determine the position of root fractures. This study was undertaken to assess the accuracy of two different apex locators in determining the position o...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International endodontic journal
دوره 37 3 شماره
صفحات -
تاریخ انتشار 2004