Osseointegration of zirconia and titanium dental implants: a histological and histomorphometrical study in the maxilla of pigs.
نویسندگان
چکیده
OBJECTIVES The purpose of the present study was to histologically compare the bone tissue responses to surface-modified zirconia and titanium implants. METHODS Threaded zirconia implants were produced using a new low-pressure injection moulding technique and thereafter surface treated by acid etching. Titanium implants with the exact shape and surface treated by sandblasting and acid etching (SLA) served as controls. Fifteen adult pigs received both implant types in the maxilla 6 months after extraction of the second and third incisors. The animals were sacrificed after 4, 8 and 12 weeks and 30 implants with surrounding bone were retrieved. RESULTS Histological evaluation showed osseous integration for both materials. Zirconia implants revealed mean peri-implant bone density values of 42.3% (SD +/- 14.5) at 4 weeks, 52.6% (SD +/- 5.7) at 8 weeks and 54.6% (SD +/- 11.5) at 12 weeks after implantation, whereas Ti-SLA implants demonstrated mean values of 29% (SD +/- 10), 44.1% (SD +/- 18) and 51.6% (SD +/- 8.6) at corresponding time intervals. With respect to the bone-implant contact ratio, the mean values for zirconia ranged between 27.1% (SD +/- 3.5) and 51.1% (SD +/- 12.4) and for Ti-SLA, it ranged between 23.5% (SD +/- 7.5) and 58.5% (SD +/- 11.4). For the parameters investigated, no statistically significant differences between both types of implants could be detected at any time point. CONCLUSIONS No statistical difference between implants could be demonstrated with any of the methods used. The limited number of animals per group, however, does not allow to conclude that there is no difference in osseointegration between the two types of implants, although the data tend to suggest such a trend.
منابع مشابه
Osseointegration of zirconia implants compared with titanium: an in vivo study
BACKGROUND Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an alternative to...
متن کاملThe Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs
Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...
متن کاملOsseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep
Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric...
متن کاملOsseointegration of zirconia implants: an SEM observation of the bone-implant interface
BACKGROUND The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the...
متن کاملComparison of zirconia and titanium implants after a short healing period. A pilot study in minipigs.
The aim of this animal study was to investigate and compare the osseointegration of zirconia and titanium dental implants. 14 one-piece zirconia implants and 7 titanium implants were inserted into the mandibles of 7 minipigs. The zirconia implants were alternately placed submerged and non-submerged. To enable submerged healing, the supraosseous part was removed, using a diamond saw. The titaniu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical oral implants research
دوره 20 11 شماره
صفحات -
تاریخ انتشار 2009