Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

نویسندگان

  • Sebastian Weingärtner
  • Mehmet Akçakaya
  • Sébastien Roujol
  • Tamer Basha
  • Christian Stehning
  • Kraig V Kissinger
  • Beth Goddu
  • Sophie Berg
  • Warren J Manning
  • Reza Nezafat
چکیده

PURPOSE To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sampled center and randomly undersampled outer k-space. The resulting undersampled 3D k-space data are then reconstructed using compressed sensing. Subsequently, T1 maps are generated by voxel-wise curve fitting of the individual interleaved images. In a phantom study, the accuracy of the 3D sequence was evaluated against two-dimensional (2D) modified Look-Locker inversion recovery (MOLLI) and spin-echo sequences. In vivo T1 times of the proposed method were compared with 2D multislice MOLLI T1 mapping. Subsequently, the feasibility of high-resolution 3D T1 mapping with spatial resolution of 1.7 × 1.7 × 4 mm(3) was demonstrated. RESULTS The proposed method shows good agreement with 2D MOLLI and the spin-echo reference in phantom. No significant difference was found in the in vivo T1 times estimated using the proposed sequence and the 2D MOLLI technique (myocardium, 330 ± 66 ms versus 319 ± 93 ms; blood pools, 211 ± 68 ms versus 210 ± 98 ms). However, improved homogeneity, as measured using standard deviation of the T1 signal, was observed in the 3D T1 maps. CONCLUSION The proposed sequence enables high-resolution 3D T1 mapping after contrast injection during free-breathing with volumetric left ventricle coverage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of free-breathing multi-slice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence

Background Quantitative myocardial T1 mapping is a promising technique for assessment of interstitial diffuse fibrosis. Recently, a novel T1 mapping sequence for free-breathing, multi-slice, myocardial T1 mapping using the sliceinterleaved T1 (STONE) has been developed [1], which was shown to provide superior accuracy compared to MOLLI [2]. However, in-vivo reproducibility and precision of this...

متن کامل

Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle

Methods Myocardial T1 and T2 mapping at 3 Tesla MR was obtained from 24 healthy volunteers (16 males and 8 females, mean age, 31±4 years). Shortened modified looklocker inversion recovery was used for T1 mapping and T2-prepared single-shot steady-state free precession was utilized for T2 mapping. Automatic motion correction was done by an elastic registration algorithm based on estimating motio...

متن کامل

Robust free-breathing SASHA T1 mapping with high-contrast image registration

BACKGROUND Many widely used myocardial T1 mapping sequences use breath-hold acquisitions that limit the precision of calculated T1 maps. The SAturation-recovery single-SHot Acquisition (SASHA) sequence has high accuracy with robustness against systematic confounders, but has poorer precision compared to the commonly used MOdified Look-Locker Inversion recovery (MOLLI) sequence. We propose a nov...

متن کامل

Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications

BACKGROUND Myocardial T1 and T2 mapping using cardiovascular magnetic resonance (CMR) are promising to improve tissue characterization and early disease detection. This study aimed at analyzing the feasibility of T1 and T2 mapping at 3 T and providing reference values. METHODS Sixty healthy volunteers (30 males/females, each 20 from 20-39 years, 40-59 years, 60-80 years) underwent left-ventri...

متن کامل

3D myocardial T 1 mapping using saturation recovery

PURPOSE To propose a 3D quantitative high-resolution T1 mapping technique, called 3D SASHA (saturation-recovery single-shot acquisition), which combines a saturation recovery pulse with 1D-navigator-based-respiratory motion compensation to acquire the whole volume of the heart in free breathing. The sequence was tested and validated both in a T1 phantom and in healthy subjects. MATERIALS AND ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 2015